Page 1
OPERATOR'S MANUAL 取扱説明書 MONITOR UNIT 表示部 MU-231 Model www.furuno.com...
Page 2
(Elemental Chlorine Free) The paper used in this manual is elemental chlorine free. ・ 機器の修理・使用方法等に関するお問い合わせは、お買い上げの販売店・代理店、最寄りの 当社支店・営業所あてへお願いします。 ・ FURUNO Authorized Distributor/Dealer お問い合わせは 本書の無断複写複製(コピー)は特定の : MAY 2011 場合を除き、当社権利侵害になります。 : AUG. 30, 2017 Printed in Japan Pub. No. OMC-44690-D2 (AKMU) MU-231 00017449213...
How to discard a used battery Some FURUNO products have a battery(ies). To see if your product has a battery, see the chap- ter on Maintenance. Follow the instructions below if a battery is used. Tape the + and - terminals of battery before disposal to prevent fire, heat generation caused by short circuit.
Continued use of the equipment can cause Do not place any object near the fire or electrical shock. Contact a FURUNO exhaust or intake vent. agent for service. Fire may result. Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire.
Page 5
Warning Labels Warning labels are attached to the equipment. Do not remove the labels. If a label is missing or damaged, contact a FURUNO agent or dealer about replacement. WARNING Name: Warning Label 1...
TABLE OF CONTENTS Note: This manual contains both English and Japanese instructions. The Packing Lists, Outline Drawings, and Interconnection Diagram are located at the back of this manual. FOREWORD ........................v SYSTEM CONFIGURATION ..................vi EQUIPMENT LISTS .......................vii MOUNTING, WIRING....................1 1.1 Preparation........................1 1.2 Flush Mount, Fixed at Front ..................
FOREWORD A Word to the Owner of the MU-231 FURUNO Electric Company thanks you for purchasing the MU-231 23.1” Monitor Unit. We are confident you will discover why the FURUNO name has become synonymous with quality and reliability. Since 1948, FURUNO Electric Company has enjoyed an enviable reputation for quality and re- liability throughout the world.
CCD camera, DVD recorder, etc. RS-485 FMD-3300, FCR-28x9, FAR-33x0, etc. RS-232C FEA-2807, FCR-28x7, etc. MONITOR UNIT MU-231 Environmental category 100-230 VAC MU-231: Protected from the weather Connectable equipment Equipment Resolution Signal FCV-1200L/1200LM Analog RGB, via IF-8000 FSV-24/24S SXGA* Analog RGB...
EQUIPMENT LISTS Standard supply Name Type Code No. Remarks Monitor Unit MU-231 Installation CP26-01900 000-019-211 1 set • Installation Materials (CP26-01901, Code Materials No.: 001-116-670, See page A-3.) • Cable Assembly (DVI-D/D S-LINK 5M, Code No.: 001-132-960-10) Accessories FP26-00401 001-387-540 1 set LCD Cleaning Cloth (19-028-3125-6, Code No.: 100-360-676-10)
Page 10
EQUIPMENT LISTS Name Type Code No. Remarks Monitor Replace- OP26-27 001-139-570 ment Kit *1: This is not available for UXGA signal. *2: For OP26-17. *3: For OP26-18/OP26-19. viii...
MOUNTING, WIRING Preparation Mounting method You can install the monitor unit as follows. See the outline drawings at the back of this manual for mounting dimensions. • Flush mount, fixed at front (standard) • Flush mount, fixed at front, with hood (option) •...
1. MOUNTING, WIRING Flush Mount, Fixed at Front Flush mount, fix at front is the standard installation method. 1. Use the flush mounting template (supplied) to make a cutout in the mounting location. 2. Attach the flush mounting sponges to the back of the monitor unit in the order shown in the figure at right.
Page 13
1. MOUNTING, WIRING 7. Set the masking panel S to each side of the monitor unit. Masking Panel S How to attach or detach the masking panel S Do the following to attach or detach the masking panel S. Reverse view of masking panel S Front side of Tab A monitor unit...
1. MOUNTING, WIRING Flush Mount, Fixed at Front, with Hood The flush mount, fixed at front method allows you to attach a hood (23) assembly OP26-25 (op- tion) to the monitor unit. Hood (23) assembly OP26-25 (Code No.: 001-139-380-01) Name Type Code No.
1. MOUNTING, WIRING 7. Set the cutouts of the hood (23) assembly to Hood (23) Knob M4 (4 pcs.) the knobs on the hood fixing plates (front). Assembly Hood Fixing Plate (Front) Cutout (4 places) 8. Press the top of the hood (23) assembly to set the knobs in the cut- Press outs.
1. MOUNTING, WIRING 6. Fasten the flush mount fixture 23 to the left, right, top and bottom of the rear of the monitor unit with the washer head screws (16 pcs.). Note: The flush mount fixtures (4 pcs.) are identical. The fixing holes are different between “top and Washer Head Screw B bottom”...
Page 17
1. MOUNTING, WIRING 3. Attach the flush mounting sponges to the top and bottom brims. Then, attach the hood packing A, the packing and the hood packing B to the right and left brims of the monitor unit from the rear side.
1. MOUNTING, WIRING Tabletop Mount You can fix the monitor unit to a tabletop, using the bracket assembly OP26-15 (option). Bracket Assembly OP26-15 (Code No.: 001-116-730) Name Type Code No. Bracket L 03-163-7712 100-366-311-10 Bracket R 03-163-7713 100-366-321-10 Spacer (23) 03-163-2071 100-305-371-10 Hole Plug...
Page 19
1. MOUNTING, WIRING 5. Remove the paper from the double-sided tape on the spacer assembly and then attach the spacer as- Attach the sembly to the bracket. spacer assemblies to these places. 6. Fasten the monitor unit to the bracket assembly with four hex. head slot bolt-B washers (M6x25).
1. MOUNTING, WIRING Flush Mount a Series Side by Side You can flush mount two or three monitor units side by side, using the optional flush mount kit OP26-18 for two monitor units or OP26-19 for three monitor units (see page vii). 1.
Replace MU-231CE with MU-231 Cut the connector of the power cable (15-565, supplied on the Local supply MU-231CE). Attach a crimp-on lug (supplied on the MU-231) to each cable core then connect the cables as in the Cable Length: 70 mm Length: 50 mm figure at right.
ADJUSTMENTS Adjust the MU-231 according to the equipment connected. Note: Sections 2.2, 2.3 and 2.4 are for Non-SOLAS. Installation Settings The [INSTALLATION SETTING] menu appears only when the power is turned on for the first time after installation. Menu INSTALLATION SETTING...
Page 23
2. ADJUSTMENTS 1. Press the or key to select the menu item to adjust on the [INSTALLATION SETTING] menu. The menu item and setting currently selected (the cursor) is shown in orange. 2. Press the or key to change the setting. 3.
2. ADJUSTMENTS How to open the [INSTALLATION SETTING] menu Turn off the monitor unit. While you hold the DISP key, press the /BRILL key to turn on the mon- itor unit. Press and hold the DISP key for more than five seconds. Note: When the "DVI PWR SYNC"...
Page 25
2. ADJUSTMENTS [RGB], [DVI1/2] menu descriptions Menu item Function Setting H_SIZE (Only for Adjust the image size horizontally. Depending on in- Horizontal size: (narrow), (wide) RGB menu) put signal V_SIZE (Only for Adjust the image size vertically. Vertical size: (narrow), (wide) RGB menu) PHASE** (Only Adjust the sample timing so that the flicker disappears and...
2. ADJUSTMENTS Video Composite Signal Setting (For Non-SO- LAS) You can adjust the VIDEO signal from the VIDEO port. The VIDEO signal is also displayed in the PIP window (see section 3.5). 1. Select the signal to adjust at the DISP selection window. 2.
2. ADJUSTMENTS The Menu Window Setting (For Non-SOLAS) 2.4.1 How to adjust the menu window You can adjust the position and transparency of the menu window on the [OSD] (On Screen Dis- play) menu. 1. Press the MENU key to show the menu. 2.
2. ADJUSTMENTS 2.4.2 How to change the signal name You can change the signal name ([RGB], [DVI1/2] or [VIDEO]) to a name (ex. the equipment name) which is easy to understand. The name is shown in the DISP selection window and the indication shown at the upper right of the screen (see section 3.4).
When you connect the monitor unit to the equipment other than FMD-3300, FCR-28x9, FAR-33x0, FAR-28x7, FEA-2807 or FCR-28x7, the control is done from the MU-231. If the keys of MU-231 are not illuminated, provide external, dimmable illumination, e.g. gooseneck lamp.
See the operator’s manual for the external equipment connected. Note 1: You can not turn on the power with the /BRILL key on MU-231. Note 2: When you connect the cables to both DVI-D1 and DVI-D2 ports, turn off the power of both equipment to turn off the monitor unit.
3. OPERATION How to Select the Source for Main Picture Select the signal to display on the entire screen as follows: 1. Press the DISP key to show the DISP selection window. The window shows the signal names as you customized them at paragraph 2.4.2. This window DVI1 disappears if there is no operation for five seconds.
MAINTENANCE, TROUBLESHOOTING NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. Maintenance Routine maintenance Regular maintenance is important for good performance. Check the following on a regular basis to keep the equipment in good condition.
LQ231U1W32F, OZP-120-12/15-J06 26S100780(LCD) 26P0023 ESSIP33A-1C (AD board) 26P0013 Parts list ELECTRICAL PARTS Model MU-231 Monitor unit MU-231 Unit PRINTED CIRCUIT BOARD Code No. OZP-120-12/15-J06 26P0023 (PSW board) ESSIP33A-1C (AD board) 26P0013 Code No. LQ231U1W32F, 26S100780 Code No. MFB52A-12HA-001, 26S0028 (FAN1)
FURUNO MU-231 SPECIFICATIONS OF MONITOR UNIT MU-231 GENERAL Display 23.1-inch color LCD Effective area 470.40 x 352.80 mm Resolution UXGA (1600 x 1200) Pixel pitch 0.294 mm (Horizon/Vertical) Brightness 400 cd/m typical Contrast 600: 1 View angle 160° typical (left/right and up/down: 80° or more) Visible distance 1.02 m nominal...
(title and/or number and date of issue of the standard(s) or other normative document(s)) For assessment, see • Test Report FLI 12-10-068 Rev.1, December 6, 2010 prepared by Furuno Labotech International Co., Ltd. This declaration is issued according to the Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility.