Item
Row
4th
File format
5th–
*4
*1 "Target electric energy(kWh)" and the target electric energy value will appear only when the data is displayed in
the graph.
*2 If the group name has not been registered, ["Group" + AE No. + "-" + Group number] will appear. If the block name
has not been registered, ["Block" + AE No. + "-" + Block number] will appear. If the energy management block
name has not been registered, ["Energy mgmt block" + AE No. + "-" + Energy management block number] will
appear.
*3 For AE No., refer to 4 "Name Display" in Chapter 1.
*4 The number of rows varies with the selected date range. (Day: 5th–52nd; Month: 5th–35th; Year: 5th–16th)
Date range: Year
413
2015:2014
Administration Dpt./Block01-1-03
Month,Administration Dpt. - Indoor Unit Electric Energy[kWh],Block01-1-03 - Indoor Unit Electric Energy[kWh],Target
electric energy[kWh],Administration Dpt. - Outdoor Temp.[ºC],Block01-1-03 - Outdoor Temp.[ºC]
1,675.17,661.93,600,0.4,0.5
2,697.38,683.71,700,0.3,3.2
3,528.63,518.26,400,4.5,3.8
Date range: Month
412
2015/04:2014/04
File sample
Administration Dpt./Block01-1-03
Day,Administration Dpt. - Indoor Unit Electric Energy[kWh],Block01-1-03 - Indoor Unit Electric Energy[kWh],Target electric
(Display
energy[kWh],Administration Dpt. - Outdoor Temp.[ºC],Block01-1-03 - Outdoor Temp.[ºC]
range: Block)
1,24.69,8.74,22,26.2,17.9
2,25.31,8.22,22,27,17.4
3,12.36,22.33,10,25.2,16.6
Date range: Day
411
2015/08/19:2014/06/01
Administration Dpt./Block01-1-03
Time,Administration Dpt. - Indoor Unit Electric Energy[kWh],Block01-1-03 - Indoor Unit Electric Energy[kWh],Administration
Dpt. - Outdoor Temp.[ºC],Block01-1-03 - Outdoor Temp.[ºC]
0:00,0.61,0.25,23.2,17.8
1:00,0.65,0.51,23.1,17.6
2:00,0.66,0.48,22.1,18.1
WT07996X02
Date
Item
range
The format of the display target and comparison target to be output is as
follows.
■ Address
<Indoor unit>
"Address" + "-" + AE No.
Line)
<PI controller>
"Address" + "-" + AE No.
+ "-" + Display item (Bar)
<Built-in Pulse Input (PI)>
"Pulse input" + "-" + AE No.
Measurement item
<AI controller or AHC>
"Address" + "-" + AE No.
Display item (Line)
■ Group
Group name
■ Block
Block name
■ Energy management block
Energy management block name
Day
hh:mm,
Data
Month
dd,
Year
mm,
Description
Format
*3
+ "-" + Address number + "-" + Display item (Bar/
*3
+ "-" + Address number + "-" + Metering device No.
*3
+ "-" + Channel No. + "-" + Display item (Bar)
*3
+ "-" + Address number + "-" + Sensor No. + "-" +
*2
+ "-" + Display item (Bar/Line)
*2
+ "-" + Display item (Bar/Line)
*2
+ "-" + Display item (Bar/Line)
Data value (Bar), Comparison data value (Bar), Target electric
energy value
*1
, Data value (Line), Comparison data value
(Line)