Group Icons - Mitsubishi Electric AE-200A Instruction Book

Air conditioning control system, centralized controller, integrated centralized control web
Hide thumbs Also See for AE-200A:
Table of Contents

Advertisement

1-1-2. Group icons

Each group icon indicates the operation condition of the group. Click the icon, and then click [Advanced] to bring up
the operation settings screen.
[1] Air conditioning unit group
ON
Interlocked
LOSSNAY OFF
*3
Unit unknown
*9
Hold ON
*14
*1 Whether or not to display the filter sign ([ON], [OFF]) can be set in the initial settings.
*2 If the LOSSNAY unit is interlocked with the operation of Mr. Slim units, "Interlocked LOSSNAY ON" icon will appear, even when the
LOSSNAY unit is operated individually.
(Applicable M-NET adapter model: PAC-SF48/50/60/70/80/81MA-E)
*3 If a LOSSNAY unit is interlocked with the operation of indoor units in multiple groups, the LOSSNAY unit may be in operation, even when the
"Interlocked LOSSNAY OFF" icon is displayed.
*4 The "Energy-saving ON" icon will appear while the Peak Cut control is performed. Even when the operation of the group is stopped due to
the Peak Cut control, the icon will appear.
*5 The Occupancy/Vacancy status icon will appear only when the remote controller in the group has an occupancy sensor. (ME remote
controller (North America: PAR-U01MEDU, Europe: PAR-U02MEDA)) The Occupancy/Vacancy status icon will appear only when [
[
] (gray), or [
*6 The Occupancy/Vacancy status icon takes priority over the "Interlocked LOSSNAY ON" and "Interlocked LOSSNAY OFF" icons.
*7 The Brightness/Darkness status icon will not appear only when the remote controller in the group has a brightness sensor. (ME remote
controller (North America: PAR-U01MEDU, Europe: PAR-U02MEDA)) The Brightness/Darkness status icon will appear only when [
(yellow), [
] (gray), or [
*8 The "Setback ON" icon takes priority over the Brightness/Darkness status icon.
*9 The "Unit unknown" icon will stay when the AE-200/AE-50/EW-50 cannot be recognized after startup. Check for proper connection of the air
conditioning units and proper group settings.
*10 The "Energy-saving ON" icon takes priority over the "Room temperature display" and "Room humidity display" icons.
*11 Display option of the room temperature ([Always show], [Show during operation], [Hide]) can be set in the initial settings.
*12 The "Room humidity display" icon will appear only when the remote controller in the group has a humidity sensor. (ME remote controller (North
America: PAR-U01MEDU, Europe: PAR-U02MEDA))
*13 Whether or not to display the humidity ([ON], [OFF]) can be set in the initial settings.
*14 The "Hold ON" icon is displayed for the AE-200A/AE-50A/EW-50A, but not for the AE-200E/AE-50E/EW-50E.
*15 Initial settings can be configured in the basic settings screen on the Initial Setting Tool, LCD, or the Web browser for initial settings. Refer to
the Instruction Book (Initial Settings) for details.
WT07996X02
OFF
Schedule set
Schedule disabled
Occupied/Vacant
*5 *6 *15
(blue)
(gray)
] (blue/gray) is selected in the initial settings.
] (yellow/gray) is selected in the initial settings.
Error
Filter sign ON
Energy-saving ON
Bright/Dark
Room temperature
display
*7 *8 *15
(red)
(yellow)
(gray)
108
Interlocked
*1 *15
LOSSNAY ON
Setback ON
*4 *10
Room humidity
display
*11 *15
(blue)
*2
*8
*12 *13 *15
] (blue),
]