Mitsubishi Electric AE-200A Instruction Book

Mitsubishi Electric AE-200A Instruction Book

Control system/centralized controller
Hide thumbs Also See for AE-200A:

Advertisement

Air Conditioning Control System

Centralized Controller

AE-200A/AE-50A/EW-50A
AE-200E/AE-50E/EW-50E
Before using the controller,
please read this Instruction
Book carefully to ensure proper
operation.
Retain this manual for future
reference.
-BACnet
Contents
Safety precautions ....................................................................2
1. Introduction .........................................................................4
1-1. Screen images used in this manual ............................................4
1-2. PC requirements .........................................................................4
1-3. Connection method .....................................................................5
2. Setting the Operating Environment .....................................6
2-1. Setting the IP address of the PC.................................................6
2-2. Disabling a proxy server .............................................................8
2-3. Installing .NET Framework ..........................................................9
3-1. Installation .................................................................................10
3-2. Uninstallation ............................................................................13
®
5-1. Screen configuration .................................................................17
5-2. Menu bar configuration .............................................................18
5-3. Setting tab configuration ...........................................................19
5-4. Initial setting procedure .............................................................20
6. Saving settings data .........................................................23
6-1. Settings data flow .....................................................................23
6-2. Backing up settings data ...........................................................23
7. Menu bar ...........................................................................24
7-1. File ............................................................................................24
7-2. AE-200/AE-50/EW-50 ...............................................................25
7-3. Help ..........................................................................................28
8. Setting screens .................................................................29
8-1. Explanation of Screen Buttons .................................................29
8-2. System Settings ........................................................................31
8-3. Group Settings ..........................................................................34
®
Settings ......................................................................35
®
network configuration and settings
examples ................................................................................57
Instruction Book
®
Setting Tool-
®
Setting Tool .....10
®
Setting Tool ......14
®
Setting Tool .......................................14
®
Setting Tool ........................................15
®
Setting Tool ..............................................16

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric AE-200A

  • Page 1: Table Of Contents

    Air Conditioning Control System Centralized Controller AE-200A/AE-50A/EW-50A AE-200E/AE-50E/EW-50E Instruction Book ® –BACnet Setting Tool– Contents Safety precautions ..............2 1. Introduction .................4 1-1. Screen images used in this manual ..........4 1-2. PC requirements .................4 1-3. Connection method ..............5 2. Setting the Operating Environment ........6 2-1.
  • Page 2: Safety Precautions

    Safety precautions ►Observe these precautions carefully to ensure safety. ►After reading this manual, pass the manual on to the end user to retain for future reference. ►The user should keep this manual for future reference and refer to it as necessary. This manual should be made available to those who repair or relocate the units.
  • Page 3 Consult your dealer for the proper disposal of the controller. Improper disposal will pose a risk of environmental pollution. Precautions for relocating or repairing the unit The controller must be repaired or moved only by qualified personnel. Do not disassemble or modify the controller.
  • Page 4: Introduction

    1. Introduction ® This manual is the Instruction Book for AE-200/AE-50/EW-50 (hereinafter referred to as “AE-200”) BACnet ® Setting Tool. The BACnet Setting Tool is dedicated software to set network settings and settings related to ® BACnet communication (also including object selection and COV/Event notification) and then set the settings to the AE-200.
  • Page 5: Connection Method

    1-3. Connection method ® The BACnet Setting Tool connects with the AE-200 using a LAN. ® Connect the PC with the BACnet Setting Tool installed to the LAN1 connector of the AE-200 via a HUB (refer to the figure below). For the LAN cable, use a cable that is compatible with category 5 or higher. ®...
  • Page 6: Setting The Operating Environment

    2. Setting the Operating Environment ® Set the operating environment of the PC to be used for the BACnet Setting Tool. 2-1. Setting the IP address of the PC ® Set the IP address of the PC to be used for the BACnet Setting Tool.
  • Page 7 (4) In the [Network Connections] window, click [Local Area Connection]. (5) In the [Local Area Connection Properties] window, click [Internet Protocol Version 4 (TCP/IPv4)] to select it, and click [Properties]. (6) In the [Internet Protocol Version 4 (TCP/IPv4) Properties] window, check the radio button next to [Use the following IP address].
  • Page 8: Disabling A Proxy Server

    2-2. Disabling a proxy server Configure the settings for the IP connection environment of the PC (disable a proxy server). ® (The screens and setting examples are when using Internet Explorer ® (1) Start up the Web browser (Internet Explorer (2) Click [Tools] in the menu bar, then click [Internet options].
  • Page 9: Installing .Net Framework

    2-3. Installing .NET Framework (1) Click [Control Panel] in the Start menu, click [Programs and Features], and check the version of the ® Microsoft .NET Framework. ® ® (2) If the version of the Microsoft .NET Framework is before 4.5, install Microsoft .NET Framework 4.5 from the URL below.
  • Page 10: Installation And Uninstallation Of Bacnet

    ® 3. Installation and uninstallation of BACnet Setting Tool ® This chapter explains how to install the BACnet Setting Tool (SetBACnet) to a PC and how to uninstall it. If you click [Cancel] in any of the steps during the installation or uninstallation, the installation or uninstallation will be canceled.
  • Page 11 Click [Browse...] to select a different installation destination folder. When done selecting the folder, click [Next] to proceed. The default installation destination folder location is [C:\Program Files\MITSUBISHI ELECTRIC CORPORATION\AE-200 BACnet Setting Tool\Ver.****]. Clicking [Disk Cost...] will display the disk capacity of each drive of the PC.
  • Page 12 (6) Executing the installation program Click [Next] to execute the installation program. Click [Cancel] to cancel the installation. (7) Confirming completion of installation Click [Close] on the window to complete the installation process. Check that the “AE-200_SetBACnet_v3000” icon ( ) is displayed in the start menu. WT07921X01...
  • Page 13: Uninstallation

    3-2. Uninstallation ® Take the following steps to uninstall the BACnet Setting Tool (SetBACnet). (Uninstallation is usually not necessary.) ® (1) Ensure that the BACnet Setting Tool (SetBACnet) is not running. Quit the program if it is. (2) Click [Control Panel] in the Start menu, and click [Uninstall a program]. (3) In the [Programs and Features] window, click [BACnet Setting Tool_v3000] to uninstall it.
  • Page 14: Connecting And Starting Up The Bacnet

    ® 4. Connecting and starting up the BACnet Setting Tool ® 4-1. Connecting the BACnet Setting Tool ® The BACnet Setting Tool communicates with the AE-200 using a LAN. ® ® Before connecting the BACnet Setting Tool to the AE-200, first disconnect the AE-200 from BACnet (check ®...
  • Page 15: Starting Up The Bacnet

    ® 4-2. Starting up the BACnet Setting Tool ® ® Double-click the BACnet Setting Tool icon (AE-200_SetBACnet_v****) to start up the BACnet Setting Tool shown in the figure on the left below. Select [New Settings] from [File] in the menu bar or select [Acquire Settings] from [AE-200/AE-50/EW-50] in the menu bar to display the screen shown in the figure on the right below.
  • Page 16: Exiting The Bacnet ® Setting Tool

    ® 4-3. Exiting the BACnet Setting Tool ® ® To exit the BACnet Setting Tool, click at the top right of the BACnet Setting Tool screen or select [Exit] from [File] in the menu bar. WT07921X01...
  • Page 17: Bacnet ® Setting Tool Screens And Setting Items

    ® 5. BACnet Setting Tool screens and setting items 5-1. Screen configuration ® The screen configuration of the BACnet Setting Tool is shown below. Switch between settings screens by selecting the menu bar, main tab, and sub tab. Menu bar Main tab Sub tab WT07921X01...
  • Page 18: Menu Bar Configuration

    5-2. Menu bar configuration Setting and operation items available from the menu bar are shown below. Menu Sub menu Setting and operation items Displays the settings screen for when making new settings. File New Settings Opens a saved settings data file, and reflects this settings data in Open Settings...
  • Page 19: Setting Tab Configuration

    5-3. Setting tab configuration Settings screens that are selected in the main tab and sub tab are as follows, and the items that can be set on each settings screen are as below. Main tab Sub tab Setting items Sets IP address information for AE-200 LAN1 (for air conditioning) System Settings Basic System ®...
  • Page 20: Initial Setting Procedure

    5-4. Initial setting procedure Initial settings procedures for the AE-200 are shown below. First, from procedures ① , ② , and onwards in the work flow below, make the basic settings for AE-200 and air conditioning system unit settings using the AE-200 Initial Setting Tool, AE-200’s LCD, or Web browser for Initial Settings.
  • Page 21 Table 5-4. Basic settings items for AE-200 using the AE-200 Initial Setting Tool, AE-200’s LCD, or Web Browser for Initial Settings (V: Settable/—: Not settable) Web Browser for Setting items Initial Setting Tool AE-200’s LCD Initial Settings Network – Unit information Basic Settings License registration –...
  • Page 22 ® 5-4-2. Initial settings procedure using the BACnet Setting Tool ® ® Perform initial BACnet settings using the BACnet Setting Tool, using the following procedure. (“No.” in the following table indicate the steps.) ® BACnet Setting Tool Setting items IP address of LAN1 (for air conditioning Menu bar system) of AE-200 [AE-200/AE-50/EW-50] —...
  • Page 23: Saving Settings Data

    6. Saving settings data 6-1. Settings data flow ® The figure below shows the flow image of the settings data when the BACnet Setting Tool is used. [Open Settings..] [Send Settings...] [Save Settings] ® [Acquire Settings...] BACnet Storage * AE-200 [Save Settings As...] Setting Tool (xml format)
  • Page 24: Menu Bar

    7. Menu bar The menu bar has three items — [File], [AE-200/AE-50/EW-50], and [Help]. 7-1. File Use [File] menu for the following operations and settings. 7-1-1. New Settings Used to create new settings information. Displays the initial status settings screen (displays default values for screen).
  • Page 25: Ae-200/Ae-50/Ew-50

    7-2. AE-200/AE-50/EW-50 Use [AE-200/AE-50/EW-50] menu for the following operations and settings. 7-2-1. Property ® Input the LAN1 IP address of the AE-200 that is the BACnet Setting Tool destination, and click [OK] to set. Set the port number to 80 (fixed). 7-2-2.
  • Page 26: Mode Setting

    7-2-4. Mode Setting ® Sets the AE-200 BACnet connection mode (Online/Offline). When switching the connection mode from [Offline] to [Online], the AE-200 will automatically restart. ® Online: The AE-200 is communicating with the central monitoring device (BACnet ® Offline: The AE-200 is disconnected from the central monitoring device (BACnet When performing [Send Settings] to the AE-200, set to [Offline].
  • Page 27: Date And Time

    7-2-5. Date and Time ® Sets the date and time in the AE-200. By selecting [Date and Time], the BACnet Setting Tool acquires from the AE-200 the date and time stored in the AE-200. Use [▲]/[▼] to set the current time, then click [Set] to update the date and time saved in the AE-200.
  • Page 28: Help

    7-3. Help [Help] menu shows the following. 7-3-1. About ® The BACnet Setting Tool program version is shown in a pop-up window. Click [OK] or at the upper right to close the window. (The following example shows version 3.0.0.0.) ® Version information is always shown on the title bar of the BACnet Setting Tool window.
  • Page 29: Setting Screens

    8. Setting screens 8-1. Explanation of Screen Buttons This explains what operations occur when screen buttons are pressed. 8-1-1. Tab screen The following shows the sample of the Setting Tool screen. ① [Add] ② [Modify] ③ [Delete] ④ [Save Settings] ⑤...
  • Page 30 8-1-2. Pop-up screen 8-1-2-1. [OK] ® Reflects the settings details in the pop-up window to the BACnet Setting Tool, and closes the pop-up window. 8-1-2-2. [Cancel] ® Closes the pop-up window, without reflecting the settings details in the pop-up window to the BACnet Setting Tool.
  • Page 31: System Settings

    8-2. System Settings [System Settings] has the [Basic System] settings screen. 8-2-1. Basic System ® Set the IP addresses of AE-200 LAN1 (for air conditioning system) and LAN2 (for BACnet 8-2-1-1. LAN1 (for air conditioning system) Set fields for the LAN1 (for air conditioning system) IP address. LAN1 can only use IPv4. Item Default value IP Address...
  • Page 32 ® 8-2-1-2. LAN2 (for BACnet ® Sets fields for the AE-200 LAN2 (for BACnet ) IP address (some items are display-only). LAN2 can only be set using IPv4. Item Description Default value IP Address Set the IP address of AE-200 (LAN2). 192.168.2.1 Subnet Mask Set the IP address network address portion.
  • Page 33 8-2-1-5. AE-200/AE-50/EW-50 Data AE-200-related data appears when [Acquire Settings] is performed. (1) Serial No AE-200 serial number appears. (2) AE-200/AE-50/EW-50 Program Version AE-200 program version appears. (3) BACnet Program Version ® AE-200 BACnet program version appears. WT07921X01...
  • Page 34: Group Settings

    8-3. Group Settings 8-3-1. Group Displays the group settings configuration set in the AE-200 Initial Setting Tool, AE-200’s LCD, or Web browser (units, remote controllers, and system controllers for each group). (Default status is all fields blank.) From the [AE-200/AE-50/EW-50] menu, click [Acquire Settings] to acquire the group settings set in the AE-200. ®...
  • Page 35: Bacnet ® Settings

    ® 8-4. BACnet Settings [BACnet Settings] has [BACnet], [Network and Device], [COV Notification], [Event Notification], [Object], [Other], and [ForcedOff Reset] settings screens. ® The following explains basic terminology used in BACnet ® <BACnet terminology> Terminology Description ® ® Number that identifies the BACnet router to which BACnet device (equipment) is connected.
  • Page 36: Other Settings

    I-Am Timer (If “0”, only the initial “I-Am” is sent, with no subsequent periodic sends.) AE-200 vender ID appears. Vender ID (MITSUBISHI ELECTRIC AC&R: 99 (fixed)) 8-4-1-2. Other Settings Sets 5 other settings items for the AE-200. Item Description Default setting Use Dry Mode Check the checkbox to use an operation mode “Dry”.
  • Page 37 8-4-1-3. Use Remote BBMD Register the AE-200 to the BBMD as an external device. Item Description Default Check the checkbox to register the AE-200 to the BBMD as an Use Remote BBMD Unchecked external device. Set the time limit (in minute increments) for the AE-200 to be registered to the BBMD as an external device.
  • Page 38 8-4-2. Network and Device From [BACnet Settings], click the [Network and Device] tab to display the [Network and Device Settings] screen. Assign IP addresses and port numbers to network and device numbers. This chapter covers settings for the following devices that exchange information with the AE-200. •...
  • Page 39 8-4-2-1. Network No. ® Network configuration is required only when a BACnet router is used. ® (Only [Local] will appear in the Network No. column when no BACnet router is used.) The maximum number of network that can be configured is 5 (including Local). Click [Add] to display the [Network No.] popup window.
  • Page 40 8-4-2-2. Device Address Registers other devices such as central monitoring devices that send and receive data with the AE-200. A maximum of 11 devices can be registered as communications devices (including broadcast). (1) Registering communications device Sets communications device information. Click [Add] to display the [Device Address] pop-up window. Item Description Default...
  • Page 41 (2) Changing communications device Changes device settings. Select the device to change and click [Modify], or double-click the [Address/Port No.] to change to display the [Device Address] pop-up window. When changing or deleting the device IP address, ensure that you check the notification destination IP ®...
  • Page 42 8-4-3. COV Notification From [BACnet Settings], click the [COV Notification] tab to display the [COV Notification Settings] screen. This assigns device numbers registered on the [Network and Device] screen to the COV notification number. By using the COV notification number set here to set COV notifications for each control item in 8-4-5 “Object”, send COV notifications such as changes in status of control items and start-stop status in accordance with each COV notification number.
  • Page 43 8-4-3-2. Notification Address (1) Setting “Notification Address” Sets the COV number notification destination device. Select the [COV No.] (left) for the device to set, and under [Notification Address] (right), click [Add] to display the [Notification Address] pop-up window. A maximum of 5 devices can be set for each COV No. (including broadcast). Item Description Default...
  • Page 44 Click [Select] to display the [Network and Device Settings - Select BACnet Device] screen (figure below), from where you can select the COV notification destination device number. This screen shows the device list set in 8-4-2 “Network and Device”. In the screen above, select (reflect) the device number and click [Select] to reflect the device information selected in [Device No.] in the [Notification Address] pop-up window.
  • Page 45 8-4-4. Event Notification From [BACnet Settings], click the [Event Notification] tab to display the [Event Notification Settings] screen. As in 8-4-3 “COV Notification”, this assigns device numbers registered on the [Network and Device] screen to the notification destination class ID. By using the notification class set here to set event notifications for each control item in 8-4-5 “Object”, send event notifications such as changes in status of control items and abnormality alarms in accordance with each notification class ID.
  • Page 46 8-4-4-2. Notification Address (1) Setting “Notification Address” Sets the notification destination device to register in the notification class ID. Select the [Notification Class ID] for the device to set, and under [Notification Address], click [Add] to display the [Notification Address] pop-up window.
  • Page 47 Click [Select] to display the [Network and Device Settings - Select BACnet Device] screen (figure below), from where you can select the event notification destination device number. This screen shows the device list set in 8-4-2 “Network and Device”. In the screen above, select (reflect) the device number and click [Select] to reflect the device information selected in [Device No.] in the [Notification Address] pop-up window.
  • Page 48 8-4-5. Object From [BACnet Settings], click the [Object] tab to display the [Object Settings] screen. Sets objects to use with the AE-200 (control items), as well as details of COV notifications and event notifications for each object. Only those items set on this screen (Use: ) can be used as control items on the AE-200.
  • Page 49 (1) Objects used for temperature setting commands from the central monitoring device Temperature setting objects that can be used differ depending on indoor unit group configuration. When setting temperature from the central monitoring device, use temperature setting objects that match the indoor unit group configuration.
  • Page 50 (2) Objects used for apportioned electricity billing function Uses the apportioned electricity billing function to store electric energy apportioned by group or interlocked unit in an accumulator object. Reads current accumulator object values for each collection cycle, and stores this in the trend log object. When using the apportioned electricity billing function, a “Charge”...
  • Page 51 8-4-5-2. Notification Setting Select the [Use] check box ( ), and set notifications (COV Notification and Event Notification) for enabled control items (objects). (1) Setting COV Notification and Event notification Double-click the control items (objects) to set, and the [Notification Setting] pop-up window as below will be displayed.
  • Page 52 *1 Select the “COV No.” from the [COV Notification Settings - Select COV No.] pop-up window below, displayed by clicking [Select]. This screen shows the COV number list registered in 8-4-3 “COV Notification”. *2 Select the [Notification Class] from the [Event Notification Settings - Select Notification Class ID] pop-up window below, displayed by clicking [Select].
  • Page 53 Whether or not COV notification and event notification settings are possible for objects is shown below. Support for COV notifications and event notifications (V: Settable/—: Not settable) Control item Object ID COV Notification COV Increment Event Notification On Off Setup BO_01xx01 —...
  • Page 54 Control item Object ID COV Notification COV Increment Event Notification Trend Log Group Apportioned LOG_01xx83 — — — Electric Energy Trend Log Interlocked Units LOG_61aa83 — — — Apportioned Electric Energy Trend Log PI controller Electric LOG_41mm84–87 — — — Energy 1–4 Trend Log Pulse Input Electric LOG_410084–87...
  • Page 55 8-4-6. Others From [BACnet Settings], click the [Object] tab to display the [Other Settings] screen. This screen displays “Restart Notification Recipients” settings. [1] Restart Notification Recipients Displays introduction sequence at AE-200 start-up, and “I-Am” periodic transmission destination device settings. Default value settings are as follows. Additionally, settings values for these items cannot be changed. Item Default setting Restart Notification Recipients...
  • Page 56 8-4-7. ForcedOff Reset From [BACnet Settings], click the [ForcedOff Reset] tab to display the [ForcedOff Reset] screen. During an ® AE-200 emergency stop, clicking the [ForcedOff Reset] button from the central monitoring device (BACnet ) will cancel the AE-200 emergency stop. This function is used when canceling an AE-200 emergency stop from the central monitoring device ®...
  • Page 57: Attachment 1 Bacnet ® Examples

    ® Attachment 1 BACnet network configuration and settings examples ® The AE-200 only supports BACnet /IP. ® The following are types of BACnet network configuration. Network configuration Description Local network Local network configuration, without going through a router ® ® BACnet router connection Configuration in which each network connects through a BACnet...
  • Page 58 ® (2) BACnet router connection ® Multiple networks can be connected via BACnet routers. ® 1. Sample network configuration with the use of BACnet routers Network No. 500 Ethernet ® BACnet Device Device ID: 51 ® Device ID: 52 BACnet IP address: 192.168.5.1 IP address: 192.168.5.2 router...
  • Page 59 <Network No.500 settings> <Global Broadcast settings> (3) IP router connection Networks connect through an IP router. 1. Sample network configuration with the use of IP routers Device ID: 32 Device ID: 31 IP address: 192.168.3.2 IP address: 192.168.3.1 ® BACnet Device Ethernet router...
  • Page 60 2. Configuring the Network and Device Settings The [Network and Device Settings] screen below shows the settings for the sample network configuration with the use of IP routers above. “Network No.” is “Local”. The use of IP routers will require the default gateway setting to be configured beforehand. ®...
  • Page 61 (4) IP router + BBMD connection Multiple networks can be connected via IP routers. Broadcast messages across networks are transferred by BBMDs. 1. Sample network configuration with the use of IP routers and BBMDs Device ID: 31 Device ID: 32 IP address: 192.168.3.1 IP address: 192.168.3.2 IP address: 192.168.3.30...
  • Page 62 The use of IP routers will require the default gateway setting to be configured beforehand. ® (Refer to 8-2-1-2 “LAN2 (for BACnet )” for details.) When using remote BBMD, configure the “Use Remote BBMD” setting beforehand. (Refer to 8-4-1-3 “Use Remote BBMD” for details.) 3.
  • Page 63 (5) IP router + Remote BBMD connection (without a connection of BBMD to the local network) Networks can also be connected via IP routers. Broadcast messages are transmitted across networks via remote BBMDs that are connected to other networks. 1. Sample network configuration with the use of IP routers and BBMDs Device ID: 32 Device ID: 31 IP address: 192.168.3.30...
  • Page 64 The use of IP routers will require the default gateway setting to be configured beforehand. ® (Refer to 8-2-1-2 “LAN2 (for BACnet )” for details.) The use of remote BBMD will require the “Use Remote BBMD” setting to be configured beforehand. (Refer to 8-4-1-3 “Use Remote BBMD”...
  • Page 65 WT07921X01...
  • Page 66 WT07921X01...
  • Page 67 WT07921X01...
  • Page 68 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is based on the following EU regulations: • Low Voltage Directive 2006/95/EC • Electromagnetic Compatibility Directive 2004/108/EC • Restriction of Hazardous Substances 2011/65/EU Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

This manual is also suitable for:

Ae-50aAe-200eEw-50aAe-50eEw-50e

Table of Contents