16.9 Event List

Event list displays the data, line number and time after decoding. It is convenience for observing the long
decoded data. (This function is only enabled when BUS state is opened.)

16.10 Delay Calibration

When use the oscilloscope to perform the actual measurement, transmit delay of probe cable may cause big
error (zero offset).
The zero offset is defined as the offset of the intersection of the waveform and the trigger level line relative
to the trigger position.
Adjusting Multipurpose knob to set delay time, which can set to -100 ns ~100 ns.
Note: This parameter setting is related to the instrument's model and the current time base scale size. The
greater the time base scale, the larger the setting step.