UNI-T UPO1000CS Series Quick Start Manual
UNI-T UPO1000CS Series Quick Start Manual

UNI-T UPO1000CS Series Quick Start Manual

Digital phosphor oscilloscope
Hide thumbs Also See for UPO1000CS Series:

Advertisement

UPO1000CS Series
Digital Phosphor Oscilloscope
Quick Start Guide
REV 1
2022.11.7

Advertisement

Table of Contents
loading

Summary of Contents for UNI-T UPO1000CS Series

  • Page 1 UPO1000CS Series Digital Phosphor Oscilloscope Quick Start Guide REV 1 2022.11.7...
  • Page 2: Copyright Information

    UNI-T is the registered trademark of Uni-Trend Technology (China) Co., Ltd. Document Version UPO1000CS-20220901-V1.00 Statement  UNI-T products are protected by patent rights in China and foreign countries, including issued and pending patents.  UNI-T reserves the rights to any product specification and pricing changes. ...
  • Page 3: Safety Requirement

    Users must follow the following conventional safety precautions in operation, service and maintenance of this device. UNI-T will not be liable for any personal safety and property loss caused by the user’s failure to follow the following safety precautions. This device is designed for professional users and responsible organizations for measurement purposes.
  • Page 4 Alternating current of device. Please check the region’s voltage range. Direct current of device. Please check the region’s voltage range. Grounding Frame and chassis grounding terminal. Grounding Protective grounding terminal. Grounding Measuring grounding terminal. Main power off. Main power on. Power Standby power supply: when the power switch is turned off, this device is not Supply...
  • Page 5 environment-friendly use period of this product is 40 years, during which it can be used safely. Upon expiration of this period, it should enter the recycling system. Safety Requirements Warning Please connect this device to AC power supply with the power cable provided; The AC input voltage of the line reaches the rated value of this device.
  • Page 6 If this device may be faulty, please contact the authorized maintenance personnel of Abnormity UNI-T for testing. Any maintenance, adjustment or parts replacement must be done by the relevant personnel of UNI-T. Do not block the ventilation holes at the side and back of this device;...
  • Page 7: General Inspection

    This chapter introduces on using the oscilloscope for the first time, the front and rear panels, the user interface, as well as the built-in help system. 3.1 General Inspection It is recommended to inspect the instrument follow the steps below before using the UPO1000CS series for the first time. (1) Check for Damages Caused by Transport If the packaging carton or the foam plastic cushions are severely damaged, please contact the UNI-T distributor of this product immediately.
  • Page 8: Before Use

    3.2 Before Use To perform a quick verification of the instrument’s normal operations, please follow the steps below: (1) Connect to the Power Supply The power supply voltage range is from 100 VAC to 240 VAC, the frequency range is 45 Hz to 440 Hz. Connect the oscilloscope to the power supply line that came with the oscilloscope or any power supply line that meets the local country standards.
  • Page 9 ① Set the attenuation coefficient in the probe menu and the switch on the probe to 10x, and connect the probe to CH1. Make sure the probe’s connector is properly connected with the oscilloscope. Connect the probe’s main clip and ground clip to the oscilloscope’s compensating signal and ground terminal respectively.
  • Page 10: Front Panel

    4. Front Panel ○ Figure 3 Front Panel Table 1 Description of Front Panel Description Description EXT (External trigger input) Screen display area terminal Multipurpose knob Horizontal control area Function menu Analog channel input terminal Run/Stop, Automatic setting Vertical control area Trigger control Control menu, copy key Default, Help menu...
  • Page 11: Rear Panel

    5. Rear Panel Figure 4 Rear Panel Table 2 Description of Rear Panel Description Description USB Device interface Pass/Fail output terminal LAN interface Safety lock 11 / 14...
  • Page 12: User Interface

    6. User Interface 11 10 Figure 5 User Interface Table 3 User Interface Icon Description Description Trigger status identification System time Timing scale LAN identification Sampling rate/Storage depth USB host identification Waveform identification MATH state identification Trigger position CH2 state identification Horizontal displacement CH1 state identification Analog channel...
  • Page 13: Operation Menu

    Press F5 to turn pages. 8. Remote Control UPO1000CS series digital phosphor oscilloscope communicates with the computer through USB interface and LAN interface to achieve remote control. Remote control is implemented based on the SCPI (Standard Commands for Programmable Instruments) command set.
  • Page 14 All the preceding causes slow refreshing of waveforms. Users can restore the factory settings so that the waveforms can be refreshed normally. 10. Appendix Contact Us If the use of this product has caused any inconvenience, please contact your local UNI-T dealer or sales center. You can send emails to infosh@uni-trend.com.cn...