5 Daily operation and quick settings ..............25 5.1 Central week profile ....................27 5.1.1 Activating the central week profile for a room group ........27 5.1.2 Ending the central week profile for a room group ........29 User manual Wilo-Geniax Central Control...
Page 4
6.1 Display outdoor temperature .................. 69 6.2 Displaying energy saving tips .................. 70 6.3 Displaying temperature specifications ..............71 6.4 Displaying unit information ..................73 6.5 Displaying contact person ..................73 6.6 Displaying symbol explanations ................74 WILO SE 04/2011...
Page 5
11.2 Setting the room temperature ................102 11.3 Lowering the room temperature ................ 103 11.4 Sensibly ventilate residential rooms ..............103 11.5 Heat evenly ........................104 11.6 Do not cover or block radiators ................104 User manual Wilo-Geniax Central Control...
Page 6
............... 105 11.8 Close roller blinds ..................... 105 12 Menu structure ......................106 12.1 Room function ......................106 12.2 Central functions ...................... 107 13 Technical information ..................... 108 13.1 Type key ........................108 13.3 Factory configuration ....................109 WILO SE 04/2011...
This note warns about dangers that could, in the event the note is disregarded, lead to property damage. This note provides useful tips for easy use of the Geniax Central Control. It also draws attention to general information. User manual Wilo-Geniax Central Control...
Page 8
[], [], [], [], [OK]: These symbols designate the buttons of the navigation button [3.2.1 Navigation but- ton, page 14]. [Function key]: This highlighting designates the corre- spondingly named function of a function key [3.2.2 Function buttons, page 14]. WILO SE 04/2011...
English 1.2 Where can you find which information? Operating concept The basic operating concept of the Geniax Central Control is described in the section 3.2 Operation and navigation [page 14]. Here you can find out how to made settings and have information displayed.
[5.5 Activating key lock, page 68]. 2.2 Application (intended use) The Wilo-Geniax Central Control is a central user inter- face. It is used for measuring, displaying and setting a room temperature. It offers the possibility to define time profiles during which one or more rooms can be heated to defined temperatures.
For your safety English 2.3 Who is allowed to do what? Wilo recommends that some functions only be changed by an expert or in consultation with an expert. This is indi- cated in the respective places in these instructions. User manual Wilo-Geniax Central Control...
Display In normal operation, the display shows the room or central main display. 3.1.1 Room main display The room main display shows various items of status information for the room in which the Central Control is located. WILO SE 04/2011...
Page 13
System status This symbol displays the current operating status of the Geniax system (e.g., heating mode, fault). See section 10 Symbols [page 99]. User manual Wilo-Geniax Central Control...
See sections 10 Symbols [page 99]. In this case, it can concert and active room or a central time profile [4.3 Central control, page 24]. WILO SE 04/2011...
Selection menus consist of a list of menu points. Every menu point leads to a further menu. Input menus Values are shown in the input menus which can be changed. Display menus In the display menus information is shown. User manual Wilo-Geniax Central Control...
Call up the help texts [back] Return to the higher level (previous) menu [Save] Save entries [Yes] Confirm dialogue [Quick] Activate quick heating up In the main display, the [Menu] and [Room]/[Central] functions are allocated to the function buttons. WILO SE 04/2011...
In order to select a menu point, press the [] and [] buttons until the selection bar is on the desired entry. • In order to change to the selected menu, press the [OK] or [] button. User manual Wilo-Geniax Central Control...
If you lightly tap on a direction button, the dis- played value will be adjusted in small steps. If you press and hold down a direction button, the dis- played value will be adjusted in larger steps. WILO SE 04/2011...
Page 19
[OK] button. • Do not apply values? In order that changed values not be applied, press the [back], [Close] or [Cancel] function key, depending on the menu display. User manual Wilo-Geniax Central Control...
Additional information is shown in the display menus. The displayed values can not be changed. • Exit display menu? In order to exit a display menu, press the »back« function button or press the [] or [OK] button. WILO SE 04/2011...
How does the temperature control work? 4.1 Principle of operation Fundamentals With the help of the Wilo-Geniax Central Control, you can adjust the room temperature of an individual room or a group of rooms to suit your personal needs. In contrast to...
Page 22
Absence time profile, active 21°C 16°C Time of day Fig. 5: Representation of a day with active absence time profile For longer all-day presences (due to illness, for example) different temperatures can be selected for day and night periods. WILO SE 04/2011...
Page 23
Week profile active active 21°C 16°C Time of day Fig. 7: Representation of a day in the week profile with three created time areas and a manual interven- tion from 13:00 hrs to 16:00 hrs User manual Wilo-Geniax Central Control...
Page 24
The room functions of the Central Control can also be excluded by the central control [7.1.1 Configuring the Central Control for the central control, page 76]. WILO SE 04/2011...
The maximum temperature specifies the highest temper- ature that can be set in the input menus. 4.2.5 Room frost protection temperature The room frost protection temperature is the temperature specification for the “Room frost protection” room mode. User manual Wilo-Geniax Central Control...
Fig. 9: Installation with one central and four room user interfaces: Rooms 1-4 are centrally controlled. The central control is indicated at the room user interface by the symbol . Room 5 is excluded from the central control. WILO SE 04/2011...
[5.3.1 “Present today” for the room, page 39]/[5.3.2 “Present until ...” for the room, page 40]. The presence time profile can be acti- vated for the room or a room group. User manual Wilo-Geniax Central Control...
Page 28
If your daily routine changes permanently, then you should change the week profile accordingly so that you do not have to keep manually changing the heating sequence [7.2 Editing the week profile, page 78]. WILO SE 04/2011...
➥ The display shows the »Central control« selection menu. 4. Use the [] and [] buttons to select the »Central inter- ventions« menu point and press [OK] or []. ➥ The display shows the »Central interventions« selec- tion menu. User manual Wilo-Geniax Central Control...
Page 30
The symbol indicates the central active “Week profile” room mode. The settings stored in the central week profile are used. WILO SE 04/2011...
[OK] or []. ➥ The display shows the »Week profile (central)« selec- tion menu. 6. Use the [] and [] buttons to select the »End« menu point and press [OK] or []. User manual Wilo-Geniax Central Control...
➥ The display shows the »Intervention« input menu. What is shown are the room target temperature and the time up to when the temperature should be main- tained that are saved in the active time profile. WILO SE 04/2011...
Page 33
7. In order to apply the values, press [OK] on the navigation button. ➥ The display shows the »Apply intervention« selection menu. 8. Use the [] and [] buttons to select the »Apply« menu point and press [OK] or []. User manual Wilo-Geniax Central Control...
2. Press the [Menu] function button. ➥ The display shows the »Menu« selection menu. 3. Use the [] and [] buttons to select the »Currently active: Intervention« menu point and press [OK] or []. WILO SE 04/2011...
2. Press the [Menu] function button. ➥ The display shows the »Menu« selection menu. 3. Use the [] and [] buttons to select the »Currently active: Intervention« menu point and press [OK] or []. User manual Wilo-Geniax Central Control...
2. Press the [Menu] function button. ➥ The display shows the »Menu« selection menu. 3. Use the [] and [] buttons to select the »Central con- trol« menu point and press [OK] or []. WILO SE 04/2011...
Page 37
➥ The display changes back to the »Central interven- tions« selection menu or to the central main display. The active time profile remains active. Start with Step 2. to input again. User manual Wilo-Geniax Central Control...
“Intervention” room mode is indicated by the symbol 2. Press the [Menu] function button. ➥ The display shows the »Menu« selection menu. 3. Use the [] and [] buttons to select the »Central con- trol« menu point and press [OK] or []. WILO SE 04/2011...
1. Press the [Central] function button in case the central main display is still not displayed. ➥ The display shows the central main display. The central active “Intervention” room mode is indicated by the symbol 2. Press the [Menu] function button. User manual Wilo-Geniax Central Control...
Page 40
➥ The display shows the central main display with the overview of the active time profiles for all the room user interfaces included in the central control. The “Intervention” room mode has been ended and the preset time profile is active again. WILO SE 04/2011...
[OK] or []. ➥ The display shows the »Time profiles« selection menu. 4. Use the [] and [] buttons to select the »Present today« menu point and press [OK] or []. User manual Wilo-Geniax Central Control...
At the end of the select period, the preset time profile is automatically activated again. 1. Press the [Room] function button in case the room main display is still not displayed. ➥ The display shows the room main display. 2. Press the [Menu] function button. WILO SE 04/2011...
Page 43
[] and [] buttons to select the »Until:« menu point and press [OK] or []. ➥ The display shows the »Present until ...« input menu. 9. Follow the instructions in step 5 to step 7. User manual Wilo-Geniax Central Control...
Page 44
Apply all values? 14. In order to apply the values, use the [] and [] buttons to select the »Apply« menu point and press [OK] or []. WILO SE 04/2011...
“Present” room mode is indicated by the symbol 2. Press the [Menu] function button. ➥ The display shows the »Menu« selection menu. 3. Use the [] and [] buttons to select the »Currently active: Present« menu point and press [OK] or []. User manual Wilo-Geniax Central Control...
“Present” room mode is indicated by the symbol 2. Press the [Menu] function button. ➥ The display shows the »Menu« selection menu. 3. Use the [] and [] buttons to select the »Currently active: Present« menu point and press [OK] or []. WILO SE 04/2011...
➥ The display shows the central main display. 2. Press the [Menu] function button. ➥ The display shows the »Menu« selection menu. 3. Use the [] and [] buttons to select the »Central con- trol« menu point and press [OK] or []. User manual Wilo-Geniax Central Control...
(due to illness, for example), you can use this time profile to define different room target tempera- tures for a room group for day and night periods. At the end of the select period, the preset time profile is automatically activated again. WILO SE 04/2011...
Page 49
6. Use the [] and [] buttons to select whether you want to set the day, month or year of the final date of you pres- ence: [] for selection to the left [] for selection to the right User manual Wilo-Geniax Central Control...
Page 50
At the end of the set period, the preset time profile is activated again. You can change the set values [5.3.7 Editing pres- ence for a room group, page 50] or end the “Present” room mode early again [5.3.8 Ending presence for a room group, page 51]. WILO SE 04/2011...
Page 51
»By day until« or »At night until« should be maintained. 16. Apply the displayed values with [OK]. ➥ The display shows the »Present« selection menu with the daily temperature and time specifications up to the end date. User manual Wilo-Geniax Central Control...
1. Press the [Central] function button in case the central main display is still not displayed. ➥ The display shows the central main display. The “Present” room mode is indicated by the symbol 2. Press the [Menu] function button. WILO SE 04/2011...
You can use this function to end the “Present” room mode for a room group early. You can only perform this function if the “Present” room mode is centrally active and the symbol is shown in the central main display. User manual Wilo-Geniax Central Control...
Page 54
➥ The display shows the central main display with the overview of the active time profiles for all the room user interfaces included in the central control. The “Present” room mode has been ended and the preset time profile is active again. WILO SE 04/2011...
➥ The display shows the »Briefly away for ...« selection menu. Absent for 2, 4 or 8 hours? 5. Use the [] and [] buttons to select the menu point which corresponds to the duration of your absence. User manual Wilo-Geniax Central Control...
At the end of the select period, the preset time profile is automatically activated again. 1. Press the [Room] function button in case the room main display is still not displayed. WILO SE 04/2011...
Page 57
7. Apply your input with [OK]. ➥ The display shows the »Absent until ...« input menu. 8. Use the [] and [] buttons to select the desired time for your return. 9. Apply your input with [OK]. User manual Wilo-Geniax Central Control...
Page 58
[OK] or []. ➥ The display shows the »Absent until« input menu. 15. Select the desired room target temperature for the time of your absence with the [] and [] buttons. 16. Apply the displayed values with [OK]. WILO SE 04/2011...
1. Press the [Room] function button in case the room main display is still not displayed. ➥ The display shows the room main display. The “Absent” room mode is indicated by the symbol 2. Press the [Menu] function button. User manual Wilo-Geniax Central Control...
1. Press the [Room] function button in case the room main display is still not displayed. ➥ The display shows the room main display. The “Absent” room mode is indicated by the symbol 2. Press the [Menu] function button. WILO SE 04/2011...
At the end of the select period, the preset time profile is automatically activated again. 1. Press the [Central] function button in case the central main display is still not displayed. ➥ The display shows the central main display. 2. Press the [Menu] function button. User manual Wilo-Geniax Central Control...
Page 62
➥ The display shows the »Determine duration« selection menu. 8. Use the [] and [] buttons to select the time up to when the lowered room target temperature should be main- tained. Apply settings? 9. Apply your input with [OK]. WILO SE 04/2011...
➥ The display shows the central main display. 2. Press the [Menu] function button. ➥ The display shows the »Menu« selection menu. 3. Use the [] and [] buttons to select the »Central con- trol« menu point and press [OK] or []. User manual Wilo-Geniax Central Control...
Page 64
➥ The display shows the »Absent« selection menu with the date and time of your return. The »With room set- tings« menu item is ticked; the room time profile set- tings stored in the individual room user interfaces are used. WILO SE 04/2011...
Page 65
At the end of the set period, the preset time profile is activated again. You can change the set values [5.4.7 Editing absence for a room group, page 65] or end the “Present” room mode early again [5.4.8 Ending absence for a room group, page 66]. User manual Wilo-Geniax Central Control...
Page 66
20. In order to apply the values, use the [] and [] buttons to select the »Apply« menu point and press [OK] or []. WILO SE 04/2011...
[OK] or []. ➥ The display shows the »Central control« selection menu. 4. Use the [] and [] buttons to select the »Central active interventions« menu point and press [OK] or []. User manual Wilo-Geniax Central Control...
You can only perform this function if the “Absent” room mode is centrally active and the symbol is shown in the central main display. 1. Press the [Central] function button in case the central main display is still not displayed. WILO SE 04/2011...
Page 69
➥ The display shows the central main display with the overview of the active time profiles for all the room user interfaces included in the central control. The “Absent” room mode has been ended and the preset time profile is active again. User manual Wilo-Geniax Central Control...
»Settings« selection menu without activating the key lock. An active key lock is indicated by the symbol the main display. In order to cancel the key lock again, press the two function buttons at the Cen- tral Control simultaneously. WILO SE 04/2011...
4. Select the »Outdoor temperature« menu point and press [OK]. ➥ The display shows the »Outdoor temperature« display menu. 5. Return with [back] to the »Information« selection menu or wait until the display automatically shows the main dis- play again. User manual Wilo-Geniax Central Control...
5. Use [] and [] to select other energy saving tips. 6. Return with [back] to the »Information« selection menu or wait until the display automatically shows the main dis- play again. WILO SE 04/2011...
6. Return with [back] or [] to the »Temperature specifica- tions« selection menu in case you want to have other temperature specifications shown, or wait until the dis- play automatically shows the main display again. User manual Wilo-Geniax Central Control...
Page 74
➥ The display shows the »Minimum« display menu. 14. Return with [back] or [] to the »Temperature specifica- tions« selection menu in case you want to have other temperature specifications shown, or wait until the dis- play automatically shows the main display again. WILO SE 04/2011...
6.5 Displaying contact person You can use this function to show the contact data of the specialist who installed your heating system to receive quick assistance in case there are problems. User manual Wilo-Geniax Central Control...
1. Press the [Room] function button in case the room main display is still not displayed. ➥ The display shows the room main display. 2. Press the [Menu] function button. ➥ The display shows the »Menu« selection menu. 3. Select the »Information« menu point and press [OK]. WILO SE 04/2011...
Page 77
➥ The display shows the brief designation of the dis- played symbol in the header. 6. Return with [back] to the »Information« selection menu or wait until the display automatically shows the main dis- play again. User manual Wilo-Geniax Central Control...
With this function, you can configure the room functions of the Central Control for central control. 1. Press [Room] in case the room main display is still not dis- played. ➥ The display shows the room main display. 2. Press [Menu]. WILO SE 04/2011...
With this function, you can configure the other rooms in a room group functions for central control. 1. Press [Central] in case the central main display is still not displayed. ➥ The display shows the central main display. User manual Wilo-Geniax Central Control...
During installation, the week profile is individually adapted to your heating habits and the spatial sit- uation. It is only necessary to re-adapt it if the cre- ated weekly routine no longer corresponds to you habits. WILO SE 04/2011...
7. Use [] and [] to enter the starting time. 8. Apply your input with [OK]. 9. In order to set the end time of the time area, select »Up to:« and use [OK] to open the input menu. User manual Wilo-Geniax Central Control...
Page 82
15. In order to set the temperature of the underfloor heating, select »Floor tempering« and use [OK] to open the input menu. 16. Use [] and [] to enter the tempering stage. 17. Apply your input with [OK]. WILO SE 04/2011...
Page 83
24. In order to enter or change other time areas, start again with step 3. Do not save week profile? 25. To not save the week profile, press [Cancel]. User manual Wilo-Geniax Central Control...
3. Use [] and [] to select the weekday whose time areas you want to edit. 4. Use [] and [] to select the time area of the selected weekday that you want to edit. 5. Use [OK] to open the selection menu for the selected time area. WILO SE 04/2011...
Page 85
12. In order to set the room target temperature, select »Temp.« and use [OK] to open the input menu. 13. Use [] and [] to enter the room target temperature. 14. Apply your input with [OK]. User manual Wilo-Geniax Central Control...
Page 86
Do not apply values? 21. In order to exit the selection menu without applying the input, press [back]. Delete time area? 22. In order to delete the time area, select »Deactivate time area« and confirm with [OK]. WILO SE 04/2011...
Page 87
Save week profile? 27. To save the week profile, press [Save]. ➥ The display shows the »Save?« dialogue. 28. In order to save the week profile, press [Yes] or return to the »Edit week profile« selection menu with [back] with- out saving. User manual Wilo-Geniax Central Control...
»Settings« »Room« »Temperature specifications« ➥ The display shows the »Temperature specifications« selection menu. Change comfort 3. In order to change the comfort temperature, select the temperature? »Comfort« menu point and press [OK]. WILO SE 04/2011...
Page 89
➥ The display shows the »Maximum« input menu. The maximum temperature determines the maxi- mum room target temperature that can be set. The value entered here can not be exceeded. 13. Use [] and [] to enter the desired temperature. User manual Wilo-Geniax Central Control...
Geniax room user interface of the room group, select the respective room name in the »Central settings« menu instead of the room group name. ➥ The display shows the »Temperature specifications« selection menu. WILO SE 04/2011...
Page 91
➥ The display shows the »Maximum« input menu. The maximum temperature determines the maxi- mum room target temperature that can be set. The value entered here can not be exceeded. 13. Use [] and [] to enter the desired temperature. User manual Wilo-Geniax Central Control...
➥ The display shows the room main display. 2. Press [Menu] and navigate to the »Day / night area« selec- tion menu via: »Settings« »Room« »Day / night area« ➥ The display shows the »Day / night area« selection menu. WILO SE 04/2011...
In order to do the setting not for the entire room group but rather for another Geniax room user interface of the room group, select the respective room name in the »Central settings« menu instead of the room group name. User manual Wilo-Geniax Central Control...
You can reset the Central Control back to its saved factory presettings. This will lead to the week profile stored in the factory becoming active [13.3 Factory configuration, page 109]. The restoration of the presettings will lead to all individual adjustments of the week profile being lost. WILO SE 04/2011...
➥ The display shows the room main display. 2. Press [Menu] and navigate to the »Presetting« selection menu via: »Settings« »Room« »Presetting«. ➥ The display shows the »Presetting« selection menu. 3. Select the »Restore« menu point and press [OK]. User manual Wilo-Geniax Central Control...
(room week pro- file), select the respective room name in the »Cen- tral settings« menu instead of the room group name. ➥ The display shows the »Presetting« selection menu. 3. Select the »View« menu point and press [OK]. WILO SE 04/2011...
4. In order to restore the presettings, confirm the dialogue with [Yes], or return (without restoring the presettings) to the »Presetting« selection menu with [back]. If no input is made, the device automatically jumps back to the main display without restoring the pre- settings. User manual Wilo-Geniax Central Control...
5. Apply your selection with [OK] or use [Close] to return to the main display without applying the entry. 7.6.2 Setting the brightness 1. Press [Room] in case the room main display is still not dis- played. ➥ The display shows the room main display. WILO SE 04/2011...
➥ The display shows the »Contrast« input menu. 4. Use [] and [] to set the desired level of contrast. 5. Apply your input with [OK] or use [back] without applying the input to return to the »Unit« selection menu. User manual Wilo-Geniax Central Control...
1. Use public or private disposal organisations when dis- posing of all or part of the product. 2. For more information on proper disposal, please con- tact your local council or waste disposal office or the supplier from whom you obtained the product. WILO SE 04/2011...
The heating of the room is switched off due to high outdoor temperatures. Room frost protection The room is heated up to frost protection temperature. Central intervention The time profile of a Geniax Central Control is active. User manual Wilo-Geniax Central Control...
Page 102
Fault/warning A fault in the Geniax System or in the Central Control has occurred. The system/Central Control has to be checked by a technician. WILO SE 04/2011...
Page 103
Outdoor temperature Current outdoor temperature is displayed. Brightness The device is ready for setting the display bright- ness. Contrast The device is ready for setting the display con- trast. User manual Wilo-Geniax Central Control...
English Energy saving tips 11 Energy saving tips The Wilo-Geniax Decentralised Pump System is a newly developed heating system which, due to its innovative, purely demand-oriented concept, can achieve energy savings of an average of 20% compared to conventional heating systems.
Only for longer absences (for example, going on holiday) does it make sense to lower the room temperatures more. In this case, the Wilo-Geniax Decentralised Pump System automatically ensures sufficient frost protection in win- ter.
Such a heat build-up causes up to 5% higher heating costs. Curtains that hang over radiators also shield the room from the warm air and increase heating costs. WILO SE 04/2011...
The energy savings which can be attained by these meas- ures are, however, quite small if heat shield insulating glass is used. Roller blinds cases should be compact and thermally well insulated. User manual Wilo-Geniax Central Control...
English Technical information 13 Technical information 13.1 Type key Example: Wilo-Geniax Central Control black Geniax Decentralised Pump System Central Control Central user interface, housing colour: Top part white, bottom part white black Optional housing colour: Top part white, bottom part black 13.2 Technical data...
22:00 hrs The end of the day period set by the Geniax System. Temperature in the night period 16°C The temperature set by the Geniax System for absence. End of the night period 06:00 hrs The end of the night period set by the Geniax System. User manual Wilo-Geniax Central Control...
Page 112
3 (available stages: 0 to 5) Floor tempering Stage 3 Tempering stage of the floor for time area 3 (available stages: 0 to 5) When delivered, time area 1 is set as default for every weekday. WILO SE 04/2011...
Page 113
-do not apply values........17 -absent............ 20, 26 -exiting............ 16, 18 -intervention .......... 21, 25 -main menu ........... 14 -present ..........20, 25 -select ............15 -principle of operation.........19 time specification .........11 navigation button ........... 6 week profile ...........19 User manual Wilo-Geniax Central Control...
Page 114
2004/108/CE appendice IV,2 et 2006/95/CE appendice III B) Hiermit erklären wir, dass die Bauarten der Baureihe : Geniax Central Control Geniax Central Control black Herewith, we declare that this product: Geniax Comfort Control Par le présent, nous déclarons que cet agrégat :...
Page 115
B'dan il-mezz, niddikjaraw li l-prodotti tas-serje jissodisfaw id- dispo izzjonijiet relevanti li Þejjin: Kompatibbiltà elettromanjetika - Direttiva 2004/108/KE Vulta baxx - Direttiva 2006/95/KE WILO SE WILO SE kif ukoll standards armonizzati adottati fil-leÞi lazzjoni nazzjonali Nortkirchenstraße 100 b'mod partikolari: 44263 Dortmund ara l-paÞna ta' qabel...
Page 117
Argentina Croatia Hungary Lebanon Saudi Arabia Taiwan WILO SALMSON WILO Hrvatska d.o.o. WILO Magyarország Kft WILO SALMSON WILO ME - Riyadh WILO-EMU Taiwan Co. Ltd. Argentina S.A. 10090 Zagreb 2045 Törökbálint Lebanon Riyadh 11465 C1295ABI Ciudad T +38 51 3430914...
Page 118
Tochter gesellschaften Bau + Bergbau Kommune Österreich WILO SE Bau + Bergbau Zentrale Wiener Argentinien, Nortkirchenstraße 100 WILO SE, Werk Hof Industrie Neudorf: Aserbaidschan, Belarus, 44263 Dortmund Heimgartenstraße 1-3 WILO Pumpen Österreich Belgien, Bulgarien, China, T 0231 4102-7516 95030 Hof...
Need help?
Do you have a question about the Geniax Central Control and is the answer not in the manual?
Questions and answers