5. If dip-switch settings are required, configure them on the external controller now.
DANGER
Deactivate power to the external controller while setting dip-switches
l
Example - Jandy AquaLink
This external controller has dip switches. Confirm they are properly
positioned to operate a heat pump.
Set dip-switch "S2" #1 to "ON". The solar option is to be used for the
l
heat pump.
Check Jandy documentation for any further dip switch settings.
l
6. If additional sensors are required on the external controller, install them on the external controller now.
Example - Pentair EasyTouch
Some controllers require an additional sensor be
connected to the external controller's power supply circuit
board at the solar connection point. The sensor is not
used but will show an error if not connected.
7. Reinstall electrical access panels on both the heat pump and external controller.
8. Reactivate power to heat pump and external controller.
9. Configure the heat pump to accept external controller signal. See "Configure for Smart Controller" below.
Configure for Smart Controller
IF UNIT IS ASLEEP,
SWIPE TO WAKE UP
PRESS "ENTER"
C
Failure to heed the following will result in injury or death.
®
:
®
and Pentair IntelliTouch
PRESS MENU
A
BUTTON
USE ARROWS TO
D
"ADVANCED"
®
:
USE ARROWS TO
B
"SYSTEM"
PRESS "ENTER"
E
Page - 21