"SET TO SWITCH
Displays
ISSUE
If when pressing the "Pool / Spa" button the display flashes the message
REMOTELY", the heat pump is using a remote relay switch or a 3-wire controller.
RESOLUTION
The Pool and Spa thermostat automatically switch when using these modes.
l
Operation manually will not be available when using these external devices. No action is required.
l
"UNIT MODEL
Displays
ISSUE
The heat pump has encountered a software error.
RESOLUTION
The model number and serial number will need to be re-entered into the system. The system will then
l
operate as normal.
l
If the issue reoccurs, please contact AquaCal

Heat Pump Not Running

ISSUE
The heat pump will not run.
RESOLUTION
1. Confirm equipment is receiving power. Is the heat pump display illuminated?
If not, confirm the main breaker (located at the power supply panel) and the disconnect switch (located near
l
the heat pump) are both turned on.
If the display still does not illuminate, it is recommended that the heat pump installer or electrician confirm the
l
heat pump is receiving power.
2. Confirm correct mode is selected.
3. Confirm thermostat is set correctly.
When heating the water is desired, the thermostat should be set above the current water temperature.
l
When cooling the water is desired, the thermostat should be set below the current water temperature.
l
4. If an error code is displayed, diagnose and correct the cause of the code.
See "Fault Codes" on page 89.
l
5. If the heat pump is using an external controller, the heat pump may not be set correctly to accept the
controller's signal.

Heat Pump's Tripping Breaker

ISSUE
The heat pump breaker(s) keeps tripping.
RESOLUTION
®
1. If AquaCal
heat pumps have been connected using a multiple heat pump configuration, the configuration
may be incorrect. Please confirm settings or contact installer of equipment.
See "Connecting Multiple Heat Pumps (Optional)" on page 25.
l
2. Have an electrician confirm breakers are correct type, in good condition, and properly sized for the heat
pump.