1.3.e Schematic Location
Schematics are located on the inside of the electrical panel.
Some schematics have been provided in the appendix of this manual. See "Schematics" on page 100.
1.3.f Connecting and Configuring Actuator and Relay-Controlled Devices
This section describes how to connect actuators, circulation pumps, and relay-controlled devices to the heat
pump.
NOTE:
Combining different brands of variable speed circulation pumps is not supported. These
brands can have different protocols that may be incompatible with each other. However,
using one brand of RS-485 equipped variable speed circulation pump with a different
brand single speed circulation pump is supported. A single speed circulation pump will
require an expansion board as it uses a relay.
DANGER
Deactivate power while routing wiring to control board.
l
Follow all National Electric Codes (NEC) and/or State and Local guidelines.
l
WARNING
Installation of this equipment by anyone other than a qualified installer can result in a safety hazard.
l
The information contained throughout the "Installation" section is intended for use by qualified installation
l
technicians familiar with the swimming Pool/Spa safety standards.
NOTICE
Failure to protect equipment against corrosive conditions will adversely affect the life of the equipment and will
l
void equipment warranty.
1. Turn off power at heat pump's power disconnect.
2. Remove heat pump's electrical access panel(s).
3. Route device wiring to the low voltage side of the electrical enclosure and label wires with masking tape and a
pen. Follow all National Electric Codes (NEC) unless State or Local guidelines supersede.
4. Attach device wires to the expansion board. See Figure 1 and 1.3.f.
5. Reattach heat pump access panel(s).
6. Apply power to heat pump.
Failure to heed the following will result in injury or death.
Failure to heed the following may result in injury or death.
Failure to heed the following may result in damage to equipment.