SMASH–Lite* Interface
(System Management Architecture for Server Hardware* by AMI*)Intel® Remote Management Module 3 User Guide
8.3
System1
The system target represents the server/blade. Power control is available on the target
system1. It contains sol1, sp1, and other sensor monitoring targets. Here sp1 stands for
Service Process Configuration.
8.3.1 Supported Properties
The supported properties of the target system1 are as follows:
Property
CurrentPowerStatus
SysIdSupported
SysIdentification
TimeOutValue
Identity
8.3.2 Supported Verbs
The supported verbs of the system1 targets are as follows:
62
Table 14: System1 - Supported Properties
This Read-Only property shows the power status of the system as ON or OFF.
The value of the property is assigned to any of the following values:
ON - If the power status of the system is on, then the value of this property
is ON.
OFF - If the power status of the system is off, then the value of this property
is OFF.
This read only property indicates if System Identification is
SUPPORTED
or
NOT SUPPORTED
This R/W property reflects the current state of system identification.
1. It can set to any of the following values:
System identification can be turned off as follows:
> Set SysIdentification=OFF
System identification can be timed ON as follows:
> Set SysIdentification=TIMED
2. Set the timeout value. The TimeOutValue property is set to TIMED and
SysIdentification property value is set to ON.
Note: If set SysIdentification=INDEFINITE, then TimeOutValue property is
set to INDEFENITE and SysIdentification property value is set to ON.
This value is R/W, which is associated with TIMED (ON) gives input in seconds
as follows:
INDEFINITE - System identification is ON for an indefinite period of time.
TIMED –System identification is ON for only a known period of time.
OFF- System identification is currently OFF.
If TimeOutValue is TIMED then set the TimeOutValue to
> Set TimeOutValue=3 (only numeric, non-zero values accepted).
This read only property gives a brief explanation of the present target and
cannot be changed.
Task
Revision 1.3