8
1 Lock Normal Operation LED indication
The lock has three LEDs that support an optical scheme with red, yellow and green.
The indication scheme is described by the figures below:
Card read (configurable)
Access granted, EAC offline or online
Access denied, EAC online
Access denied, EAC offline
Lock mechanism is blocked when
Error in lock, maintenance required
Time to replace the battery
Battery reached end of life, lock
NOTE: Ensure the tamper switch activator does not fall out of the cover during assembly.
A tamper event message will be sent to the EAC panel if tamper is enabled. The "Error in
lock" indication is also shown instead of the POST flashes if the battery is not accepted as
new after a power-on-reset.
2 Lock Maintenance LED Indication
Some special LED indication schemes are used during lock maintenance actions:
Enter configuration
closing
disabled
Fig. Lock Normal operation LED indication
mode
Fig. Lock maintenance LED indication
One yellow flash (.25 seconds)
One green flash (1 second)
One red flash (1 second)
Three red flashes (.5 second each)
Continuous red flashes blocked when closing
(.125 seconds every 1 second)
Ten red flashes (.125 seconds each),
maintenance required; repeated if lock can't
close
Continuous yellow flashes (.25 seconds every
5 seconds)
Continuous red flashes, (.25 seconds every 5
seconds)
Five yellow flashes (.125 seconds each)