9 Install Door Position Switch (DPS)
1. Insert DPS into the raceway on the latch edge of the door.
2. Push wires through raceway toward lock prep.
3. Push DPS firmly into place by hand.
Note: DO NOT TAP SWITCH WITH ANY TOOL.
4. Install magnet into door frame. Push firmly into place by hand.
5. To connect DPS to lock controller per diagram, refer to the wiring in
Step #12-2.
10 Install Gasket and Outside Escutcheon
For exterior applications, use a weatherseal gasket between escutcheon and outside door surface.
To apply weatherseal gasket:
1. Carefully remove the backing from the gasket (Fig. 10A).
2. Apply gasket to escutcheon:
Note: Install ribbon cable with cable exiting down.
a. Starting in one place, press the adhesive side
of the gasket firmly against the escutcheon.
b. Work around the escutcheon, pressing the
sticky side of the gasket firmly against the
escutcheon edge.
c. The gasket should be aligned so that all edges
of the escutcheon are covered.
3. Place the outside escutcheon against the door,
while directing mounting posts through the door.
3A. For fire rated doors: Feed ribbon cable with connector
from outside of door through weatherseal gasket and fire stop
plate (Fig. 10B).
3B. For non-fire rated doors: Feed ribbon cable with
connector from outside of door through weather seal gasket
(if used) and weather conduit (not shown).