PR100 Cylindrical Lock
2 Install Strike
Install strike in the door frame (Fig.2).
3 Install Latchbolt
1. Install latch with beveled bolt facing the strike.
2. Attach with two screws but DO NOT tighten completely at this time.
IMPORTANT: Latch bevel must match door bevel and
deadlocking latch must stop on strike when door is closed.
4 Door Options
A. Fire Stop Plate (P/N 52-0033)
Fire-rated doors require a fire stop plate on the outside
of the door (Fig. 4A).
1. For wood doors, drill (2) 1/8 x 1-1/4" deep holes into
the door. For metal doors, drill (2) 9/64 x 1-1/4" deep
holes into the door, if not already present.
Refer to template for fire-stop prep locations.
2. Attach with flap up and out using (2) #10 x 1-1/4"
self-tapping screws for wood and metal doors.
B. Weather Conduit (52-2847)
Install weather conduit on
exterior doors only (Fig. 4B).
1. Carefully insert the weather conduit into the
ribbon cable hole on the inside of the door.
2. Place the O-ring around the weather conduit
on the outside and up against
the door (Fig. 4C).
(2) #8-32 x 3/4"
Latch Screws
Fig. 2
Strike
Deadlocking Latch
Fig. 3B
NON FIRE-RATED
Centerline of Latch
Front and Strike
Outside of Door
Ribbon Cable Hole
Fig.4B
1-800-810-WIRE • www.sargentlock.com • A8079D
Fig. 3A
Outside of Door
(2) 1/8" Diameter
Holes Required
Fire Stop Plate
(2) #10 x 1-1/4
Screws for Wood
and Metal Doors
(2) Through-bolt Holes
Fig. 4A
O-Ring
Fig.4C
Outside of Door
7