Download Print this page

Sargent ASSA ABLOY PR100 Installation Instructions Manual page 9

Advertisement

PR100 Cylindrical Lock
7 Install Lock
1. Feed wires into the lock body hole from outside of door (Fig.7A).
2. Slide lock body into cross-bore hole from outside (locked side)
of the door (Fig.7B).
3. Lock body must engage both the latch unit prongs
and tail piece (Fig. 7C).
IMPORTANT:
Door must remain open during installation. Use door stop.
Lock body must be centered in the door.
Inside of Door
8 Secure Lock to the Door
1A. For wood door: Feed wires up through the
routed channel (Fig. 8).
1B. For metal door: Feed wires and connector
through inside of door (not shown).
2. Slide inside rose assembly and spacer bushing over lock
body and secure with (2) #10-32x1-1/4" through-bolts.
3. Secure latch with (2) additional #6 x 3/4" self-tapping screws.
4. Tighten latch screws securely.
Fig. 7B Detail
Inside of Door
Outside of Door
Cylindrical
Lock
Body
Fig. 7A
Fig. 8
1-800-810-WIRE • www.sargentlock.com • A8079D
1
Wire Harness
(From Lock Body)
Fig. 7C Detail
3
Latch Screws
9