SN200/210 Cylindrical Lock

Wiring Diagrams

6
Product
1-Black
2-Red
ACCESS CONTROL DEVICES: SN200/210 Mortise, ElectroLynx wire Color / Function assignments
SN200
12VDC
(Reader)
SN210
SN200
NEG
POS
SN210
*Diagrams on following pages
Wiegand Operation Mode:
Red LED 'ON' when powered.
Presenting a 13.56MHz or 125 kHz credential causes LED to briefly turn green and then return to
red state.
PIN 8 (Yellow - GREEN_LED)
PIN 6 (Blue – RX COM)
PIN 4 (Green – Data 0)
PIN 2 (Red – Reader POS)
PIN 1 (Black – Reader NEG)
PIN 3 (White – Data 1)
PIN 5 (Orange – RX NO)
PIN 7 (Brown - EGND)
OSDP Operation Mode*:
*LED/Sounder control and Tamper status communicated over OSDP serial protocol
PIN 8 (Yellow – n/a)
PIN 6 (Blue – RX COM)
PIN 4 (Green – RS-485A)
PIN 2 (Red – Reader POS)
PIN 1 (Black – Reader NEG)
PIN 3 (White – RS-485B)
PIN 5 (Orange – RX NO)
PIN 7 (Brown - EGND)
A8282A • 800-810-WIRE (9473) • www.sargentlock.com
8 PIN CONNECTOR
3-White
4-Green
5-Orange
WIEGAND
WIEGAND
RX
OSDP
OSDP
DATA_1
DATA_0
NO
RS-485B
RS-485A
PIN 4 (Tan –DPS COM )
PIN 2 (Gray – Lock POS)
PIN 1 (Violet – Lock NEG)
PIN 3 (Pink – DPS NC)
PIN 4 (Tan –DPS COM )
PIN 2 (Gray – Lock POS)
PIN 1 (Violet – Lock NEG)
PIN 3 (Pink – DPS NC)
6-Blue
7-Brown
8-Yellow
*
RX
EGND
GREEN_LED
n/a
COM
EGND
INPUT
n/a
9
4 PIN CONNECTOR
1-Violet
2-Gray
3-Pink
4-Tan
12/24 VDC
DPS
DPS
(LOCK RELAY)
NEG
POS
NC
COM
Note: NC = Normally Closed
NO = Normally Open