Northern Telecom DMS-100 Series Maintenance Manual page 211

Distributed processing peripheral, recovery and routine
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Procedure 6-12
Recover AMA data from DIRP - DIRP block number not known
Step
Description
Enter:
>FILTER ENABLE
>DUMP CALL DETAILS
This filters through the entire Parallel File
looking for the record defined. One record
should match the data input into the FILTER.
When the utility locates the record, the block
number and the record is output, as shown
below:
>>>BLOCK NO: 15
*HEX ID: AA STRUCTURE CODE: 007000C CALL CODE:.....
This is the last block received at the data
center. To verify the entire block against the
one the data center provided enter:
>DUMP CALL DETAILS <block number> 1
Add 1 to the block number and that is the
first block of AMA data that the data center
has not received. Reference NTP
297-1001-128 or 297-1001-830.
5
In this step, locate the last block the data
center requires. We require the record that
was broken down in step 2 that was the first
block of data received after the DPP was
recovered.
>FILTER DISABLE
>FILTER DELETE <first structure code>
example: >FILTER DELETE 00700
>FILTER ADD <structure code from step 2>
example: >FILTER ADD 00001
response:
>>>adding .... structure code: 00001
record code: 00001
call code:
Automatic message accounting (AMA) messages 6-21
Notes
(continued)
DPP Recovery and Routine Maintenance Guide BCS35 and up
(continued)