Northern Telecom DMS-100 Series Maintenance Manual page 178

Distributed processing peripheral, recovery and routine
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-8 DPP man-machine interface
Table 5-1
ERRMAP entries to log message cross-reference
ERRMAP message, alarm, level (notes)
SITE FILE ERROR, MAJOR, 0
STAT FILE ERROR, MINOR, 0
CP NOT AVAIL., MAJOR, 1
(If an NT6M94AA PCA is mounted in slots A7
and B7 of the DPP chassis, then, 56K polling is
equipped.)
297-1001-537 Standard 01.02 December 1993
(continued)
Associated log message(s) (notes)
EXCIDX FILE FULL
LOGIDX FILE FULL
BAD xxxIDX FILE
INVALID SITE DATA FILE
NO SITE DATA ON DISK
SITDAT FILE yyyyyy ERROR: ee
DISK BUFFER NOT AVAILABLE
TDYSTS FILE yyyyyy ERROR: ee
BOOTCP FILE yyyyyy ERROR: ee
CP ACTIVATE FAIL
CP AUDIT FAIL
CP BOOT LIST EMPTY
CP DATA ERR
CP DMA Test Failed
CP I/O FAILURE
CP LOAD FAIL
CP PRG Checksum Test Failed
CP RAM Test Failed
CP RESTART FAIL
CP ROM CKSM ERR
CP ROM Checksum Test Failed
CP SCC Loopback Test Failed on Channel x
CP TASK ERR
CP TIMEOUT
xxxxxx FILE yyyyyy ERROR: ee
(continued)