6-4 Automatic message accounting (AMA) messages
Procedure 6-2
AMA messages - procedures
1
(log message)
EXCESSIVE INVALID
BLOCKS
(w/o 56K polling)
2
Alarm Level:
No processor switch
3
Customer-Selected
Alarm Level
4
Other Alarm Indications
5
System Recovery Action
6
Craftsperson Activity
Procedure 6-3
AMA messages - procedures
1
(log message)
EXCESSIVE INVALID RE-
CORDS
2
Alarm Level:
No processor switch
297-1001-537 Standard 01.02 December 1993
cause: exception report printed whenever the daily count
of invalid call record blocks reaches the threshold
value specified by the VALPARM INVALID site
data entry.
Reason Code = 26
Corresponds to ERRMAP entry: EXCESS INVALID
BLKS
System Default:
Type: Major
Type:
Default:
Status Panel: Major
Customer-Selected
Status Panel:
None
Verify and correct the data coming into the DPP system
from the DMS-100. Consult with technical assistance
personnel before proceeding.
cause: exception report printed whenever the daily count
of invalid call records reaches the threshold value
specified by the VALPARM INVALID site data
entry.
Reason Code = 26
Corresponds to ERRMAP entry: EXCESS INVALID
RECS
System Default:
Type: Major
(continued)
Level: 0
Level:
Audible: Major
Audible:
Level: 0
Need help?
Do you have a question about the DMS-100 Series and is the answer not in the manual?