5-6 DPP man-machine interface
Table 5-1
ERRMAP entries to log message cross-reference
ERRMAP message, alarm, level (notes)
STANBY PROC N/A, MAJOR, 0
NO BLK LAST HR, MINOR, 0
DSI STNBY FAIL, MINOR, 0
DSI PRIME FAIL, MAJOR, 1
D_RAM ERROR, MAJOR, 1
SIO-1 FAILURE, MAJOR, 1
SIO-2 FAILURE, MAJOR, 1
1 MMI LINK DOWN, MINOR, 0
2 MMI LINKS DOWN, MAJOR, 0
297-1001-537 Standard 01.02 December 1993
Associated log message(s) (notes)
STANBY PROC NOT AVAILABLE
PROC FORCE SELECTED - NON REDUNDANT
COMM DOWN TO STANBY PROC
NO BLOCK LAST HOUR
B0 (or) B2 DSI COLD START
B0 (or) B2 DSI COMM FAIL
B0 (or) B2 DSI DMA FAIL
B0 (or) B2 DSI TIME OUT
B0 (or) B2 DSI WARM START
B0 (or) B2 DSI NOT READY
B0 (or) B2 DSI COLD START
B0 (or) B2 DSI COMM FAIL
B0 (or) B2 DSI DMA FAIL
B0 (or) B2 DSI TIME OUT
B0 (or) B2 DSI WARM START
B0 (or) B2 DSI NOT READY
D_RAM ERROR xx AT yyyy
A0 SIO TEST FAILED
A1 SIO TEST FAILED
A2 SIO TEST FAILED
A3 SIO TEST FAILED
A4 SIO TEST FAILED
A5 SIO TEST FAILED
A6 SIO TEST FAILED
A7 SIO TEST FAILED
MMI LINK #x DOWN
BOTH MMI LINKS DOWN
(continued)