6-2 Automatic message accounting (AMA) messages
Procedure 6-1
AMA messages - procedures
1
(log message)
BX.25 INTER-TASK COMM
ERROR
(w/56K polling)
2
Alarm Level:
N/A
3
Customer-Selected
Alarm Level
4
Other Alarm Indications
5
System Recovery Action
6
Craftsperson Activity
297-1001-537 Standard 01.02 December 1993
cause: the polling task on the Main processor can't
communicate with the 56K Comm processor.
Generally, any error producing this message will
also be caught by the RFT task or MP/CP audit
task.
Reason Code = N/A
Corresponds to ERRMAP entry: N/A
System Default:
Type: N/A
Type:
Default:
Status Panel:
Customer-Selected
Status Panel:
Polling ceases.
a. If the message persists, reboot the Comm
processor.
i)
Enter:
(at the terminal)
>CP BOOT ACT (cr)
(to load the contents of the
BOOTCP file to the active 56K
Comm processor)
System response:
list of file names and version num-
bers stored in the file BOOTCP, as
they are loaded.
ii) If the error message does not repeat, procedure
complete.
iii) If the error message repeats, go to step b.
b. Reboot the main processor
(continued)
Level: N/A
Level:
Audible:
Audible: