Vent Take-Off - Valor H6 Installation Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

Preparation
Convert Vent Take-Off (if required)
This unit is supplied with a top facing vent take-off
which can be fi eld-converted to a rear facing vent take-
off . Please note that the rear facing take-off requires
the installation of the heat shield on top of the heater
case as indicated unless fi tted with optional HeatShift.
1. Remove top facing take-off (6 screws).
Remove top take-off (6 screws)
2. Swivel take-off and install as a rear facing one
(6 screws).
3. Reinstall heat shield to top of appliance case
(2 screws).
Swivel take-off so it
is oriented towards
rear and reinstall to
heater (6 screws)
Rear take-off with required heat shield
36
Reinstall heat
shield to top of
appliance
(2 screws)

Vent Take-Off