Getting started

First time operation

When operating your new fireplace for the first time,
some vapors may be released due to the burning of
curing compounds used during manufacturing. They
may cause a slight odor and could cause the flames
to be the full height of the firebox, or even slightly
higher, for the first few hours of operation.
It is also possible that these vapors could set off any
smoke detection alarms in the immediate vicinity.
These vapors are quite normal on new fireplaces.
We recommend opening a window to vent the
room. After a few hours of use, the vapors will have
disappeared and the flames will be at their normal
height.
Valor safety gas shut-off
For your safety, Valor fireplaces are fitted with a
flame supervision device which will shut-off the gas
supply if, for any reason, the pilot flame goes out.
This device incorporates a fixed probe, which senses
the heat from the pilot flame. If the probe is cool,
the device will prevent any gas flow unless manually
lighting the pilot. See the full Fireplace and Lighting
Information card attached to the fireplace or as
reproduced in Appendix A of the Installation Manual.

Vent Safety Switch

Your fireplace is equipped with a vent safety switch
which, when activated, will turn off the burner and
pilot if the vent is blocked, disconnected, or if there is
excessive down draught.
If the safety switch is activated, wait for it to cool off
before trying to light the appliance again. The safety
switch will cool off and reset itself automatically after
25 to 30 minutes.
In the event that the safety switch is activated again,
contact your dealer or a qualified service technician
for inspection.
Should the safety switch require replacement, only
use parts supplied by Miles Industries.
Locating fi replace and lighting information
 WARNING
Do not attempt to access the card while
the fi replace is hot! Let the fi replace cool
fi rst before touching it!
The Fireplace and Lighting Information card is located
under the firebox.
To access the card, remove the barrier screen, the
fret or bottom panel., and pull the card out.
There is important information on both sides of the
card. It must be left with the fireplace when you are
done.
Fireplace
model
739MN
FOR NATURAL GAS
POUR LE GAZ NATUREL
Serial
number
CIRCULATING FAN KIT 755CFK
VENTILATEUR POUR CIRCULATION D'AIR 755CFK
120V, 60Hz, LESS THAN 1A
#4003360-741, #4003293-742, #4003313-745, #4003426-765, #4004666 772
24,000
6,500
3.2"
5.0"
739N 10000
750
120V, 60Hz, MOINS DE 1A
4006176N/01
7