Appliance Preparation
If You Are Installing HeatShift ONLY
To be eff ective, the HeatShift system requires that an
internal convection baffl e located above the fi rebox
inside the appliance case be removed to allow the hot
air fl ow to convect upwards into ducts installed on the
fi replace. Takeoff collars also need to be installed on
top of the fi replace.
See "Appendix D - HeatShift™" on page 70 for more
details regarding HeatShift installation and planning.
DO NOT perform these steps if you are not
installing the optional HeatShift kits!
Remove Convection Baffl e
Remove the convection baffl e from the appliance. It is
held in place by 3 screws located right behind the upper
edge of the fi replace opening. Recycle this panel as it is
no longer needed.
f i r e - p a r t s . c o m
Top of fi replace shown transparently for clarity.
 WARNING
The H3 fireplace requires the removal
of the internal convection baffle for the
HeatShift system to function properly—
read instructions carefully!
34
Optional HeatShift
Install HeatShift Take-Off Collars
1. Remove the two cover plates on top of the appli-
ance case (8 screws each).
2. Install the take-off collars on the holes on top of the
appliance's case (8 screws each).
 WARNING
A l l F O U R ( 4 ) t a k e o f f s M U S T B E
C O N N E C T E D T O P L E N U M ( S ) .