Table 24: 12-Ribbon Patch and Breakout Cables Available from Juniper Networks
Cable Type
Connector Type
24-Fiber MPO Connectors
You can use patch cables with 24-fiber MPO connectors to connect two supported transceivers of the
same type—for example, 2x100GE-SR-to-2x100GE-SR.
Figure 19 on page 49
shows the 24-fiber MPO optical lane assignments.
Figure 19: 24-Fiber MPO Optical Lane Assignments
NOTE: You must order cables with the correct polarity. Vendors refer to these crossover cables
as
key up to key up , latch up to latch up , Type B , or Method B . If you are using patch panels
between two transceivers, ensure that the proper polarity is maintained through the cable plant.
The MPO optical connector for the CFP2-100G-SR10-D3 is defined in
Hardware Specification and Section 88.10.3 of IEEE STD 802.3-2012 . These specifications include the
following requirements:
• Recommended Option A in IEEE STD 802.3-2012.
• The transceiver receptacle is a plug. A patch cable with a socket connector is required to connect to
the module.
• Ferrule finish shall be a flat-polished interface that is compliant with IEC 61754-7.
• Alignment key is key up.
Fiber Type
Cable Length
10 m
Section 5.6 of the CFP2
(Continued)
Juniper Model
Number
MTP-4LC-S10M
49