Copy of Safety Decal

Listed/Nom: Vented Gas Fireplace Heater / Foyer au Gaz à Évacuation
Certified to/Certifi pour:
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
C #: 4001172
NATURAL GAS: Model G800EH-NG
Minimum supply pressure
5.0"
3.8"
Manifold pressure high
1.1"
Manifold pressure low
# 35
Orifice size
Minimum input
19,500
Maximum input
36,000
Altitude
0-4500 ft/pi
PROPANE GAS: Model G800EH-LP
Minimum supply pressure
11"
Manifold pressure high
10"
Manifold pressure low
6.4"
# 51
Orifice size
27,000
Minimum input
34,000
Maximum input
0-4500 ft/pi
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #761-969). Fan Part # 761-917.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur. Installer l'appareil
selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes
ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure
si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est
fournie.
This vented gas fireplace heater is not for use with air filters.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
For Use Only with Barrier (Part #761-038/P )
Electrical supply/Alimentation électrique 115VAC, 1.5A, 60Hz.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. CATEGORY I.
FOYER AU GAZ À ÉVACUATION -
CANADIAN ENERGY
PERFORMANCE
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
VERIFIED
Natural Gas / Gaz naturel 58.73%
RENDEMENT
Propane Gas / Gaz propane 57.94%
ÉNERGÉTIQUE
EP5011169
VÉRIFIÉ
Part #: 920-615a
For the State of Massachusetts, installation
Colour: Everything black on grey except what is highlighted is printed red.
and repair must be done by a plumber or
Size: File@100% 9.117''W x 6.045''H
gas fitter licensed in the Commonwealth of
Massachusetts.
Sept. 20/22 : Created Draft
Oct. 25/22:
Changed orifice size
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
*Printer: Start serial sequence @ 000001
length.
For the State of Massachusetts, the
appliances individual manual shut-off must
be a t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
6
| Grandview
G800EH Gas Fireplace
®
é
CSA/ANSI Z21.88-2019 • CSA-2.33-2019
CSA 2.17-2017
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle G800EH-NG
Pression d'alimentation minimale
WC/C.E. (1.25 kPa)
Pression manifold - haute
WC/C.E. (0.94 kPa)
Pression manifold - basse
WC/C.E. (0.27 kPa)
DMS
Taille de l'orifice
D bit calorifique minimal
é
Btu/h (5.71 kW)
D bit calorifique maximal
é
Btu/h (10.55 kW)
Altitude
(0-1372 m)
APPAREIL FONCTIONNANT AU GAZ PROPANE
Modèle
G800E
WC/C.E. (2.74 kPa)
Pression d'alimentation minimale
WC/C.E. (2..49 kPa)
Pression manifold - haute
WC/C.E. (1.60 kPa)
Pression manifold - basse
DMS
Taille de l'orifice
Btu/h (7.91 kW)
D bit calorifique minimal
é
Btu/h (9.96 kW)
D bit calorifique maximal
é
(0-1372 m)
Altitude
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE. CATÉGORIE I.
Decal Location
DO NOT REMOVE DECAL FROM UNIT.
Duplicate S/N
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
H-LP
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
Utiliser uniquement avec l'écran ( n ° 761-038/P )
CATEGORY I / CATÉGORIE I
585
Serial No./ No de série
585
Minimum Clearances to Combustibles / Non-Cool Wall—Clean Finish
Dégagements minimaux par rapport aux matériaux combustibles
Mantel Clearances from
Fireplace Opening /
D
(A) 28" (711 mm) at max. depth
C
Side Wall Clearance
from Fireplace Opening /
B) Min. 25" (635 mm)
A
F
Ceiling from Top of
B
Fireplace Opening:
C) Min. 36-1/2" (927 mm)
Mantel Depth:
D) Max. 12" (305 mm)
Alcove Clearances:
E) Min. Width 84" (2134 mm),
E
F) Max. Depth 36" (914 mm)
Minimum Vent Clearances:
DOOR SEAL: Please
Horizontal Top
check that the door is
Horizontal Side
properly sealed
Horizontal Bottom 1-1/2" (38 mm)
Vertical Vent
(See Instruction Manual
for detailed instructions)
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Made in Canada/ Fabriqué au Canada
Remove bottom cover—decal will
be on the floor of the unit
(on one side)
2" (51 mm)
1-1/2" (38 mm)
1-1/2" (38 mm)
920-615a