Copy Of Safety Decal - Regency Fireplace Products Horizon HZ40E Owners & Installation Manual

Hide thumbs Also See for Horizon HZ40E:
Table of Contents

Advertisement

This is a copy of the label that accompanies each HZ40E-NG11 and HZ40E-LP11 Direct Vent Gas Fireplace. We have printed a copy of the contents here
for your review.
NOTE: Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of Safety Decal

Listed/Nom: VENTED GAS FIREPLACE HEATERS / APPAREIL DE CHAUFFAGE AU GAZ À ÉVACUATION.
Certified to/Certifi :
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
C #: 4001172
NATURAL GAS: Model HZ40E-NG11
Minimum supply pressure
5.0"
Manifold pressure high
3.5"
Manifold pressure low
1.6"
Orifice size
# 40
Maximum input
26,000 Btu/h
Minimum input
18,000 Btu/h
Altitude
0-4500
PROPANE GAS: Model HZ40E-LP11
Minimum supply pressure
11"
Manifold pressure high
10"
Manifold pressure low
6.4"
Orifice size
# 53
Maximum input
25,500 Btu/h
Minimum input
21,000 Btu/h
Altitude
0-4500
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si
ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si une trousse certifiée est utilisée.
This vented gas fireplace heater is not for use with air filters.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
For Use Only with Barrier (Part # 258-013) Follow installation instructions.
Fan (Part # 258-917)/Ventilateur (pièce n°258-917)
Electrical supply / Alimentation électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 64.44%
RENDEMENT
Propane Gas / Gaz propane 66.75%
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
Part #:
920-002a
For the State of Massachusetts, installation
Colour:
Black on grey except what is indicated as being printed red.
and repair must be done by a plumber or
Size:
(File at 100%) 9.318''W x 5.892''H
gasfitter licensed in the Commonwealth of
Material:
2 ml silver matt polyester (DPM SMS)
Massachusetts.
Dec. 17/18:
Created draft
Jan. 22/19:
Rev A - Remodeled decal and added ETL logo at the bottom
For the State of Massachusetts, flexible con-
nectors shall not exceed 36 inches in length.
*Printer: Start serial sequence @ 00200001
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
é
ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle HZ40E-NG11
WC/C.E. (1.25 kPa)
Pression d'alimentation minimale
WC/C.E. (0.87 kPa)
Pression de sortie (manifold) - basse
WC/C.E. (0.40 kPa)
Pression de sortie (manifold) - max.
DMS
Taille de l'orifice
(7.61 kW)
D bit calorifique maximal
é
(5.28 kW)
D bit calorifique minimal
é
ft/pi
(0-1372 m)
Altitude
APPAREIL FONCTIONNANT AU GAZ PROPANE
Modèle HZ40E-LP11
WC/C.E. (2.73 kpa)
Pression d'alimentation minimale
WC/C.E. (2.49 kPa)
Pression de sortie (manifold) - basse
WC/C.E. (1.59 kPa)
Pression de sortie (manifold) - max.
DMS
Taille de l'orifice
(7.47kW)
D bit calorifique maximal
é
(6.15 kW)
D bit calorifique minimal
é
ft/pi
(0-1372 m)
Altitude
Decal Location
Duplicate S/N
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LES PORTES VITRÉES CERTIFIÉES AVEC L'APPAREIL
Utiliser uniquement avec un écran de protection (n°258-013). Suivre les consignes d'installation.
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada/ Fabriqué au Canada
502
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
Serial No./ No de série
502
Minimum Clearances to Combustibles /
Dégagements minimaux par rapport aux matériaux combustibles
Side Walls/Murs latéraux
A
8" (203mm)
Ceiling/Plafond
B
B
22" (559mm)
D
F
Min. Mantel Height/Hteur min.
manteau
A
C
17" (432mm)
C
Max. Mantel Depth/Prof. max.
manteau
D
13" (330mm)
E
Alcove Width/Largeur alcôve
E
84" (1524mm)
Alcove Depth/Prof. alcôve
DOOR SEAL: Please
F
36" (2134mm)
check that the door is
(See Instruction Manual for
properly sealed
detailed instructions)
Remove Faceplate (see manual for instructions)
with the faceplate removed, the rating plate will
be located on the left hand side of the unit. It will
be located in-between the inner and outer firebox
(see picture).
DO NOT REMOVE DECAL FROM UNIT.
Regency Horizon ® HZ40E-11 Gas Fireplace
safety decal
920-002a
|
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz40e-ng11

Table of Contents