Aeration Adjustment

The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a
more yellow flame.
Note:
Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.
Pull lever forward to open - push back to close.
Air shutter lever - located in the center of the unit under the firebox

Electrical Access and Installation

78
| Grandview
G800EH Gas Fireplace
®
Minimum Air Shutter Opening:
NG
LP
CAUTION: C a r b o n w i l l b e
The electrical access panel is on the right side of the unit (when facing
the front of unit).
1.
Remove panel by removing three (3) screws.
2.
Remove center knockout to run cable through the access panel and
install supplied clamp.
3.
Attach wires from cable to supplied white receptacle and secure to
gang box. Screw the receptacle cover to gang box. Reinstall panel
by securing three (3) screws removed in step 1.
4.
The 120 volt power cord supplied with appliance will need to be
plugged into the receptacle only once the install is complete.
1/4" (6 mm)
3/8" (9.53 mm)
produced if air shutter
is tightly closed.