This is a copy of the label that accompanies Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located
on the front inside base of the unit, visible when the outer front panel is removed.
NOTE: Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of Safety Decal

Listed/Nom: VENTED GAS FIREPLACE HEATERS / APPAREIL DE CHAUFFAGE AU GAZ À ÉVACUATION.
Certified to/Certifi :
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
C #: 4001172
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
NATURAL GAS: Model: CV40EPV-NG/CB40EPV-NG
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
PROPANE GAS: Model: CV40EPV-LP/CB40EPV-LP
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by
local codes. See owner's manual for details. This appliance is supplied with a conversion kit.
L'appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code ANSI Z223.1, ou CSA-B149.1 Natural Gas and
Propane Installation Code en vigueur.
L'appareil doit être installé conformément à la norme CAN/CSA-Z240, Série MM, Maisons mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction
and Safety Standard. Si ces normes ne sont pas applicables, veuillez vous référer à la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C
Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si les règlements
For Use Only with Barrier CV40EPV - 1 sided (Part # 940-435/P) & CB40EPV 3 sided (Part # 940-438/P,940-439/P,940-440/P) Follow installation instructions.
Utiliser uniquement avec l'écran CV40EPV -1 face (n°940-435/P) & CB40EPV - 3 faces (n°940-438/P,940-439/P,940-440/P) . Suivre les consignes d'installation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Electrical supply / Alimentation électrique 115VAC, 1.5 A, 60Hz.
Part No. 946-556 Heatwave Kit may be used. Le système Heatwave (pièce n°946-556) peut être
VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION -
Model/Modèle :
CV40EPV-NG
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 60.02%
RENDEMENT
Propane Gas / Gaz propane 60.85%
ÉNERGÉTIQUE
EP5011169
VÉRIFIÉ
Part #:
919-918b
For the State of Massachusetts, installation
Colour:
Black on grey except what is indicated as being printed red.
and repair must be done by a plumber or
Size:
(File at 100%) 9.19"w x 6.15"h
gas fitter licensed in the Commonwealth of
Material:
Massachusetts.
Oct 5/18:
Created draft
For the State of Massachusetts, flexible con-
Nov. 21/18:
Rev. A - added efficiencies as per R/D
Jan. 29/19:
Rev B - Remodeled decal + added ETL logo at the bottom
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
é
ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
GAZ NATUREL : Modèle CV40EPV-NG/CB40EPV-NG
5.0"
WC/C.E. (1.25 kPa)
Pression d'alimentation minimale
3.8"
WC/C.E. (0.94 kPa)
Pression de sortie (manifold) - Haute
1.1"
WC/C.E. (0.27 kPa)
Pression de sortie (manifold) - Basse
# 42
DMS
Taille de l'orifice
28,500 Btu/h
(8.33 kW)
D bit calorifique maximal
é
15,500 Btu/h
(4.54 kW)
D bit calorifique minimal
é
0-4500
ft/pi
(0-1372 m)
Altitude
GAZ PROPANE :Modèle CV40EPV-LP/CB40EPV-LP
11"
WC/C.E. (2.73 kPa)
Pression d'alimentation minimale
Pression de sortie (manifold) - Haute
10.5"
WC/C.E. (2.62 kPa)
Pression de sortie (manifold) - Basse
2.9"
WC/C.E. (0.72 kPa)
Taille de l'orifice
# 53
DMS
D bit calorifique maximal
é
28,500 Btu/h
(8.35kW)
D bit calorifique minimal
é
15,500 Btu/h
(4.54 kW)
Altitude
0-4500
ft/pi
(0-1372 m)
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
Decal Location
Duplicate S/N
À UTILISER AVEC LES PORTES VITRÉES HOMOLOGUÉES POUR L'APPAREIL
utilisé.
CV40EPV-LP
476
DO NOT REMOVE THIS LABEL
/ NE PAS ENLEVER CETTE ÉTIQUETTE
Serial No./ No de série
476
Minimum Clearances to Combustibles /
Dégagement minimum des matériaux combustibles
Side Walls / Murs latéraux
Min. 120in²
A 8.5" (216 mm)
Ceiling / Plafond
B
B
D
F
Min. Mantel Height /Hteur Min
Manteau
A
C 9" (229 mm) with 12" mantel
C
Max. Mantel Depth/Profondeur Max
Manteau
D 12" (305 mm)
E
Alcove Width/Largeur Alcôve
E 84" (1524 mm)
Alcove Depth/Profondeur Alcôve
DOOR SEAL: Please
F 36" (2134 mm)
check that the door is
(See instruction manual for detailed instructions)
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada/ Fabriqué au Canada
CB40EPV-NG
Remove barrier glass from unit (refer to manual)
lift out the outer liner base glass once the glass
has been removed the rating plate will be attached
to a small black chain as seen below.
DO NOT REMOVE DECAL FROM UNIT
City Series CB40EPV |
safety decal
37-1/2" (953 mm)
(Voir manuel pour plus de détails)
CB40EPV-LP
919-918b
5