Copy Of Safety Decal; Decal Location - Regency Fireplace Products City Series CC40LE-NG12 Owners & Installation Manual

Table of Contents

Advertisement

safety decal
This is a copy of the label that accompanies Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located
on the front inside base of the unit, visible when the outer front panel is removed.
NOTE: Regency
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
®

Copy of Safety Decal

Listed/Nom: VENTED GAS FIREPLACE / FOYER AU GAZ À ÉVACUATION
Certified to/Certifi :
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
C #: 4001172
NATURAL GAS: Model: CC40LE-NG12/CC40RE-NG12
5.0 "
Minimum supply pressure
Manifold pressure - High
3.8 "
Manifold pressure - Low
1.1"
Orifice size
# 42
Maximum input
28,500 Btu/h
Minimum input
15,500 Btu/h
Altitude
0-4500
PROPANE GAS: Model: CC40LE-LP12/CC40RE-LP12
Minimum supply pressure
11"
Manifold pressure - High
10.5 "
Manifold pressure - Low
2.9"
Orifice size
# 53
Maximum input
28,500 Btu/h
Minimum input
15,500 Btu/h
Altitude
0-4500
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by
local codes. See owner's manual for details. This appliance is supplied with a conversion kit.
L'appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code ANSI Z223.1, ou CSA-B149.1 Natural Gas and
Propane Installation Code en vigueur.
L'appareil doit être installé conformément à la norme CAN/CSA-Z240, Série MM, Maisons mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction
and Safety Standard. Si ces normes ne sont pas applicables, veuillez vous référer à la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C
Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si les règlements
For Use Only with Barrier CC40LE - Left Corner (Part # 940-485/P,940-440/P) & CC40RE Right Corner (Part # 940-485/P,940-439/P) Follow installation instructions.
Utiliser uniquement avec l'écran CC40LE -Coin gauche (n°940-485/P,940-440/P) & CC40RE - Coin droit (n°940-485/P,940-439/P) . Suivre les instructions d'installation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Electrical supply / Alimentation électrique 115VAC, 1.5 A, 60Hz.
Part No. 946-535 Power Vent Horizontal Termination City Series may be used. La terminaison horizontale d'évacuation forcée (pièce n 946-535) peut être
Part No. 666-945 Inline Power Vent City Series may be used. L'évacuation forcée en ligne
VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUELS. CATEGORY I.
FOYER AU GAZ À ÉVACUATION -
Model/Modèle :
CC40LE-NG12
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 55.23%
RENDEMENT
Propane Gas / Gaz propane 56.06%
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
Part #:
920-555
For the State of Massachusetts, installation
and repair must be done by a plumber or
Colour:
Black on grey except what is indicated as being printed red.
gas fitter licensed in the Commonwealth of
Size:
(File at 100%) 9.2"w x 6.03"h
Massachusetts.
Material:
Start serial sequence at 955000001
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
June 27/22:
Created draft
length.
For the State of Massachusetts, the
appliances individual manual shut-off must
be a t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
6
| City Series CC40E-12
é ANSI Z21.88-2019 • CSA-2.33-2019
CSA 2.17-2017
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle
CC40LE-NG12/CC40RE-NG12
Pression d'alimentation minimale
WC/C.E. (1.25 kPa)
Pression de sortie (manifold) - Haute
WC/C.E. (0.94 kPa)
Pression de sortie (manifold) - Basse
WC/C.E. (0.27 kPa)
Taille de l'orifice
DMS
(8.33 kW)
D bit calorifique maximal
é
(4.54 kW)
D bit calorifique minimal
é
ft/pi
(0-1372 m)
Altitude
APPAREIL FONCTIONNANT AU GAZ PROPANE
Modèle
CC40LE-LP12/CC40RE-LP12
WC
(2.73 kpa)
Pression d'alimentation minimale
WC/C.E. (2.62 kPa)
Pression de sortie (manifold) - Haute
WC/C.E. (0.72 kPa)
Pression de sortie (manifold) - Basse
DMS
Taille de l'orifice
(8.35kW)
D bit calorifique maximal
é
(4.54 kW)
D bit calorifique minimal
é
ft/pi
(0-1372 m)
Altitude
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE. CATÉGORIE I.
CC40LE-LP12

Decal Location

Duplicate S/N
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
À UTILISER AVEC LES PORTES VITRÉES HOMOLOGUÉES POUR L'APPAREIL
City Series (pièce n 666-945) peut être utilisée.
o
CC40RE-NG12
581
Serial No./ No de série
581
Minimum Clearances to Combustibles /
Dégagements minimaux par rapport aux matériaux combustibles
Side Walls / Murs latéraux
J
A
36" (914 mm)
H
Ceiling / Plafond
B
37-1/2" (953 mm)
B
Min. Mantel Height/Hteur Min Manteau
A
D
C
9" (229 mm)
C
Max. Mantel Depth/Profondeur Max
Manteau
D
12" (305 mm)
Alcove Width/Largeur Alcôve
F
E
84" (1524 mm)
E
Alcove Depth/Profondeur Alcôve
F
36" (2134 mm)
DOOR SEAL: Please
check that the door is
(See Instruction Manual for
detailed instructions)
properly sealed
(Voir manuel pour plus de détails)
o
utilisée.
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Made in Canada/ Fabriqué au Canada
CC40RE-LP12
Remove barrier glass from unit (refer to manual) lift
out the outer liner base glass once the glass has been
removed the rating plate will be attached to a small
black chain as seen below.
DO NOT REMOVE DECAL FROM UNIT
920-555