NOTE: This fireplace is rated for both commercial & residential use.

Copy of Safety Decal

This is a copy of the label that accompanies this Direct Vent Gas Fireplace. A copy of the label is posted here for your review. The safety label is located at
the left side of the gas valve on the front, inside the base of the unit. It is visible when the outer front panel is removed.
• Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Listed/Nom: VENTED GAS FIREPLACE HEATER /
Certified to / Certifi :
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
C # 4001172
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
NATURAL GAS: Model: CP60E-NG
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
PROPANE GAS: Model: CP60E-LP
11"
Minimum supply pressure
Manifold pressure - High
10.5" WC/C.E. (2.62 kPa)
2.9"
Manifold pressure - Low
Orifice size
# 50
36,000 Btu/h
Maximum input
Minimum input
19,500 Btu/h
Altitude
0-4500
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by
local codes. See owner's manual for details. This appliance is supplied with a conversion kit.
L'appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code ANSI Z223.1, ou CSA-B149.1 Natural Gas and
Propane Installation Code en vigueur.
L'appareil doit être installé conformément à la norme CAN/CSA-Z240, Série MM, Maisons mobiles, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas
applicables, veuillez vous référer à la norme ANSI/NCSBCS A225.1/NFPA 501A.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si les règlements
locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Une trousse de conversion est fournie avec cet appareil.
For Use Only with Barriers (Part #940-544/P, #940-545/P, #940-546/P) Follow installation instructions.
Utiliser uniquement avec l'écrans CP60E (n° 940-544/P, n° 940-545/P, n° 940-546/P). Suivre les instructions d'installation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Electrical supply / Alimentation électrique 115VAC, 2.5A, 60Hz.
Part No. 946-535 Power Vent Horizontal Termination City Series may be used. La pièce n 946-535 Horizontal Power Vent Termination City Series peut être utilisée.
Part No. 666-945 Inline Power Vent City Series may be used. La pièce n 666-945 Inline Power Vent City Series peut être utilisée.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. CATEGORY I.
FOYER AU GAZ À ÉVACUATION -
Model/Modèle :
CP60E-NG
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz nature
RENDEMENT
Propane Gas / Gaz propane 62.48%
ÉNERGÉTIQUE
EP5011169
VÉRIFIÉ
Part #:
920-471
For the State of Massachusetts:
Colour:
Black on grey except what is indicated as being printed red.
Installation and repair must be done
Size:
(File at 100%) 9.11"w x 6.27"h
by a plumber or gas fitter licensed in
Material:
the Commonwealth of Massachusetts.
Start serial sequence at 570000001
Flexible connectors shall not exceed 36
Nov. 8/21:
Created draft
inches (914 mm) in length.
No. 18/21:
Updated clearances
Requires the installation of a carbon
monoxide alarm in accordance with
NFPA 720 and a CO alarm with battery
backup in the same room where the
gas appliance is installed.
The appliance's individual manual
shutoff must be a t-handle type valve.
6
| City Series CP60E
é ANSI Z21.88-2019 • CSA-2.33-2019
CSA 2.17-2017
GAZ NATUREL : Modèle CP60E-NG
5.0"
WC/C.E. (1.25 kPa)
Pression d'alimentation minimale
3.8"
WC/C.E. (0.94 kPa)
Pression de sortie (manifold) - Haute
1.1"
WC/C.E. (0.27 kPa)
Pression de sortie (manifold) - Basse
# 32
DMS
Taille de l'orifice
39,000 Btu/h
(11.42 kW)
D bit calorifique maximal
é
21,000 Btu/h
(6.15 kW)
D bit calorifique minimal
é
0-4500
ft/pi
(0-1372 m)
Altitude
GAZ PROPANE : Modèle CP60E-LP
WC/C.E. (2.73 kpa)
Pression d'alimentation minimale
Pression de sortie (manifold) - Haute
WC/C.E. (0.72 kPa)
Pression de sortie (manifold) - Basse
Taille de l'orifice
DMS
(10.54 kW)
D bit calorifique maximal
é
(5.71 kW)
D bit calorifique minimal
é
ft/pi
(0-1372 m)
Altitude
o
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE. CATÉGORIE I.
60.21%

Decal Location

Remove the centre access panel on the outer trim.
Data plate will be next to the gas valve, as shown
below.
Remove
Duplicate S/N
FOYER AU GAZ À ÉVACUATION
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
(See instruction manual for detailed instructions/Voir manuel pour plus de détails)
DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LES PORTES VITRÉES CERTIFIÉES
o
CP60E-LP
DETAIL A
SCALE 1 : 12
570
Serial No./ No de série
570
Minimum Clearances to Combustibles /
Dégagement minimaux par rapport aux matériaux combustibles
Back Wall/Mur du fond
Ceiling/Plafond (from fireplace top opening/d'après l'ouverture
sur le haut du foyer)
Mantel/Manteau (from fireplace top opening/d'après l'ouverture
sur le haut du foyer)
Mantel Depth (Max.)/Profondeur max. du manteau
Alcove Width/Largeur alcôve
Alcove Depth/Profondeur alcôve
Convection Air Outlet (Min.)/Sortie d'air de convection (min.)
DOOR SEAL: Please check that the door is properly sealed
JOINT DE PORTE : Veuillez vérifier que la porte est correctement scellée.
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada/ Fabriqué au Canada
Decal
8" (203 mm)
52" (1321 mm)
9" (229 mm)
12" (305 mm)
95" (2413 mm)
111" (2819 mm)
180 square inches
920-471
A