Owner's Information; Copy Of Safety Decal; Decal Location - Regency Fireplace Products Grandview G800C Owners & Installation Manual

Table of Contents

Advertisement

owner's information

This is a copy of the label that accompanies each Grandview™ G800C Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
NOTE: Regency
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
®

Copy of Safety Decal

Listed/Nom: Vented Gas Fireplace Heater / Foyer au Gaz à Évacuation
Certified to/Certifi pour:
é
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
C #: 4001172
NATURAL GAS: Model G800C-NG
Minimum supply pressure
5.0"
Manifold pressure high
3.8"
Manifold pressure low
1.1"
Orifice size
# 42
Minimum input
15,000
Maximum input
27,000
Altitude
0-4500 ft/pi
PROPANE GAS: Model G800C-LP
11"
WC/C.E. (2.74 kPa)
Minimum supply pressure
Manifold pressure high
10.5"
WC/C.E. (2.61 kPa)
2.9"
Manifold pressure low
# 53
Orifice size
Minimum input
14,500
Maximum input
26,500
0-4500 ft/pi
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1.
This appliance must be installed in accordance with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable,
ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #761-977). Fan Part # 761-979.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1. Installer l'appareil selon la norme 24 CFR, Part 3280, Manufactured Home
Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C
Standard for Recreational Vehicles. Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U.
seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de
conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
For Use Only with Barrier (Part #761-038/P )
Electrical supply/Alimentation électrique 115VAC, 1.5A, 60Hz.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. CATEGORY I
FOYER AU GAZ À ÉVACUATION -
CANADIAN ENERGY
PERFORMANCE
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
VERIFIED
Natural Gas / Gaz naturel 54.17%
RENDEMENT
Propane Gas / Gaz propane 53.64%
ÉNERGÉTIQUE
EP5011169
VÉRIFIÉ
Part #: 920-168d
For the State of Massachusetts, installation
Colour: Everything black on grey except what is highlighted is printed red.
and repair must be done by a plumber or
Size: File@100% 9.117''W x 6.045''H
gas fitter licensed in the Commonwealth of
Nov. 1/19 : Created Draft
Massachusetts.
Jan 6, 2020: Removed reference to CSA standard
Mar. 17/21: Updated CSA/ANSI date
For the State of Massachusetts, flexible con-
Sept. 16/21:Update P.4.1 data
nectors shall not exceed 36 inches in length.
Jan 25/22: Added Category 1
July 4/22: Changed wording
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
6
| Grandview
G800C Gas Fireplace
®
ANSI Z21.88-2019
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle G800C-NG
Pression d'alimentation minimale
WC/C.E. (1.25 kPa)
Pression manifold - haute
WC/C.E. (0.94 kPa)
Pression manifold - basse
WC/C.E. (0.27 kPa)
Taille de l'orifice
DMS
D bit calorifique minimal
é
Btu/h (4.4 kW)
Btu/h (7.91 kW)
D bit calorifique maximal
é
(0-1372 m)
Altitude
APPAREIL FONCTIONNANT AU GAZ PROPANE
Modèle
G800C
Pression d'alimentation minimale
Pression manifold - haute
WC/C.E. (0.72 kPa)
Pression manifold - basse
DMS
Taille de l'orifice
Btu/h (4.25 kW)
D bit calorifique minimal
é
Btu/h (7.77 kW)
D bit calorifique maximal
é
(0-1372 m)
Altitude
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE. CATÉGORIE I

Decal Location

DO NOT REMOVE DECAL FROM UNIT.
Duplicate S/N
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
-LP
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
Utiliser uniquement avec l'écran ( n ° 761-038/P )
536
Serial No./ No de série
536
Minimum Clearances to Combustibles / Rear Vent—Clean Finish
Dégagements minimaux par rapport aux matériaux combustibles
0" Clearance to
combustibles from /
Top, sides, bottom and rear of unit
Mantel Clearances from
D
Fireplace Opening /
C
(A) 20-1/2" (521 mm) at max. depth
Side Wall Clearance
from Fireplace Opening /
A
B) Min. 26-1/2" (673mm)
F
Ceiling from Top of
B
Fireplace Opening:
C) Min. 36-1/2" (927 mm)
Mantel Depth:
D) Max. 19" (483 mm)
Alcove Clearances:
E) Min. Width 84" (2134 mm),
E
F) Max. Depth 36" (914 mm)
Minimum Vent Clearances:
Horizontal Top
DOOR SEAL: Please
Horizontal Side
check that the door is
Horizontal Bottom 1-1/2" (38 mm)
properly sealed
Vertical Vent
(See Instruction Manual for detailed instructions)
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Made in Canada/ Fabriqué au Canada
(on one side)
2" (51 mm)
1-1/2" (38 mm)
1-1/2" (38 mm)
920-168d
Remove bottom cover—decal will
be on the floor of the unit

Advertisement

Table of Contents
loading

Table of Contents