Case CX235C SR Operator's Manual page 73

Crawler excavator
Table of Contents

Advertisement

Indicates that the engine oil level is low.
An alarm sounds. Stop the engine and re-
move the ignition key, and then inspect the
oil level.
NOTE: If the measures above are not performed im-
mediately when this message is displayed, the engine
stops automatically.
• Over heat
Indicates that the engine coolant tempera-
ture is high. An alarm sounds. Lower the
engine speed. If the temperature does not
go down, stop the engine and remove the
ignition key. Wait for the temperature of the
cooling system to go down, and then in-
spect the coolant level inside the reservoir
tank and radiator. Check the radiator and oil
cooler. (Refer to page 6-23).
• Boost temp high
Indicates that the temperature of the tur-
bocharger air that is being supplied to
the engine is abnormally high. An alarm
sounds. The engine automatically enters
idling mode as a preventative measure.
Stop the machine, operate the engine at
idling speed, and wait until the message
disappears. If the turbocharger air tempera-
ture on the display screen continues to rise,
the engine stops automatically.
your CASE CONSTRUCTION Dealer.
• Alternator
Indicates that there is a problem in the al-
ternator. An alarm sounds. Stop the en-
gine and remove the ignition key, and then
inspect the alternator. Consult your CASE
CONSTRUCTION Dealer.
• Check engine
Indicates that there is a problem (short or
disconnection) in the electrical system of the
engine. An alarm sounds. Stop the engine
and remove the ignition key, and then in-
spect the electrical system. Consult your
CASE CONSTRUCTION Dealer.
• Elec. problem
Indicates that there is a problem in the elec-
trical system. An alarm sounds. In this case,
stop the engine and remove the ignition key,
and then investigate the cause or consult
your CASE CONSTRUCTION Dealer.
• Engine stop
3 - CONTROLS/INSTRUMENTS
• Improper shut down
• Check camera
• Push DPD switch to activate
• Do not operate
• Manual/Auto DPD re-gen
Consult
• Over load
• Low coolant
• Air filter
• Low fuel
3-21
Indicates that the emergency stop switch
operated. An alarm sounds. To enable the
engine to be started again, the switch must
be canceled.
Perform low idling for at least 5 min. before
stopping the engine.
Indicates that there is a problem (short or
disconnection) in the monitor camera con-
nection.
Press the DPD switch to regenerate DPD.
(Refer to page 3-36).
Do not operate because the DPD is regen-
erating. (Refer to page 3-36).
Now being manually or automatically regen-
erated. (Refer to page 3-36).
The load is excessive. Reduce the load.
Indicates that there is insufficient coolant.
An alarm sounds. Stop the engine and re-
move the ignition key. Wait for the tem-
perature of the cooling system to go down,
and then inspect the coolant level inside the
reservoir tank and radiator. (Refer to page
6-23).
Perform maintenance of the air cleaner filter.
The fuel in the fuel tank is low. Fill the tank
with fuel.

Advertisement

Table of Contents
loading