Case CX235C SR Operator's Manual page 226

Crawler excavator
Table of Contents

Advertisement

4. Place a receptacle of a suitable capacity under the
reservoir drain plugs, remove the reservoir drain plugs
and allow the remainder of the fluid to flow out.
5. Change the suction filter and the return filter. See
"Cleaning and replacement of the suction filter" and
"Replacing the return filter".
6. Install the reservoir drain plugs.
7. Fill the reservoir with new hydraulic fluid. See "Filling
the reservoir".
8. Replace the cover plate seal if required and install the
cover plate on the reservoir.
ATTENTION: Before you start the engine, it is very impor-
tant that you bleed air from all the hydraulic components.
See "Bleeding air from the hydraulic components".
9.
Start and run the engine with no load for approxi-
mately five minutes.
10. Move each control several times to remove any air in
the system.
11. Swing the upperstructure evenly left to right two com-
plete turns or more.
12. Place the machine in position and then stop the en-
gine.
13. Check the oil level in the hydraulic reservoir and add
oil as required and check that there are no air bubbles
in the hydraulic reservoir.
6 - MAINTENANCE
6-42
13
E703CA80