Case CX235C SR Operator's Manual page 169

Crawler excavator
Table of Contents

Advertisement

6. Use the proportional switch to operate the concrete
crusher.
NOTICE: In Bucket mode, do not carry out operation us-
ing auxiliary line. If you do that the warning message
"Auxiliary set-up required" will be displayed with intermit-
tent whistle sound. Stop operation immediately and carry
out auxiliary set-up.
NOTE: To prevent failure or damage to the tool, make
sure that you select the correct circuit configuration and
flow rate and pressure for the tool.
Auxiliary hydraulic circuit flow patterns
Flow patterns can be selected from the 20 shown below.
NOTE: The number of setting patterns is 10 maximum.
1 flow
210 l/min (55.5 US gpm)
196 l/min (51.8 US gpm)
182 l/min (48.1 US gpm)
166 l/min (43.9 US gpm)
146 l/min (38.6 US gpm)
129 l/min (34.1 US gpm)
111 l/min (29.3 US gpm)
94 l/min (24.8 US gpm)
74 l/min (19.5 US gpm)
50 l/min (13.2 US gpm)
Option pressure setting
An option pressure from 19 - 34.5 MPa (2756.0 - 5004.2
psi) can be selected in 0.5 MPa (72.5 psi) increments.
4 - OPERATING INSTRUCTIONS
2 flows
420 l/min (111.0 US gpm)
406 l/min (107.3 US gpm)
392 l/min (103.6 US gpm)
376 l/min (99.3 US gpm)
356 l/min (94.0 US gpm)
339 l/min (89.6 US gpm)
321 l/min (84.8 US gpm)
304 l/min (80.3 US gpm)
284 l/min (75.0 US gpm)
260 l/min (68.7 US gpm)
4-41
29
EC3339BB