Setting-Out Line Point - Sokkia im-101 Operator's Manual

Im-100 series intelligence measurement station
Table of Contents

Advertisement

• Scale factor settings can be set in the screen shown at
right.
8. Press [OK] on the third screen of step 7 to define the
baseline. <Set-out line> is displayed. Move to setting-line
measurement.
"16.2 Setting-out Line Point"/"16.3 Setting-out Line Line"
• Press [Sy=1] to set scale factor y to "1".
• Press [1 : **] to change the grade display mode to "1 : * * =
elevation : horizontal distance".
• It is also possible to perform setting-out line measurement by pressing [S-O LINE] when allocated to the OBS
mode screen.
 Allocating [S-O LINE]: "33.12 Allocating Key Functions".

16.2 Setting-out Line Point

Setting-out line point measurement can be used to find the required point coordinate by inputting the length
and offset based on the baseline.
• Before performing setting-out line point, the baseline must be defined.
1st Pt.
PROCEDURE
1. Select "Point" in <Set-out line>
Y direction
X direction
Length
Offset
Required point
A z m t h
H c a l c
H m e a s
S c a l e X
S c a l e Y 1. 000091
Sy=1
G r a d e
S e t - o u t l i n e
P o i n t
L i n e
Baseline
S e t - o u t l i n e
P o i n t
L i n e
68
16. SETTING-OUT LINE
93 20
31
13. 003m
17. 294m
1. 000091
Sy=Sx
O K
% - 2 . 6 6 9
1:
%
OK
2nd Pt.