Coordinates Setting-Out Measurement - Sokkia SET2CII Operator's Manual

Intelligent total station
Table of Contents

Advertisement

20 SETTING-OUT MEASUREMENT
20.2 Coordinates setting-out measure-
ment
@
This measurement is used t o set out the point of a certain coordi-
nate away from the reference point (the instrument station).
@
After input of the coordinatesfor the point t o be set out, the SET2C
calculates the setting out horizontal angle and horizontal distance
and stores the values in the memory. By selecting the horizontal
angle and then the horizontal distance setting out functions, the
required coordinate location can be set out. The Z-coordinate can
also be set out using the setting out coordinate function.
To recall the setting-out coordinate data from coordinate data
stored on an IC card, please refer to P.109.
3
Coordinate
- - -- --
-
- -
setting-out data input'
-
- -
-
-
- .
-
.
-
-
-- - -
- .
- -
Theodolite mode or Basic mode
: For Coordinate setting out
data input mode
4
Input N-coordinate
setting-out data
@
Input range :
-9999999.999 t o 9999999.999
@
Least input : 0.001
@
Data storage period :
About a week (Power-off possible)
f a
Correct the value
(set value to
0
E x ~ t from the Input
(to Basic mode)

Advertisement