ARM DSTREAM-HT Getting Started Manual page 35

Hide thumbs Also See for DSTREAM-HT:
Table of Contents

Advertisement

DSTREAM-HT Getting Started Guide
If the above steps do not resolve the issue,
Cyclic Redundancy Check (CRC) error
CRC errors occur if there is a mismatch between the CRC configuration, which is enabled or
disabled in Arm Development Studio, and the generated CRC output from the target.
Indicated by: A red Frame and General LEDs in the Errors LED section on the probe.
Solution
To check that your debug configuration and target configurations match, use the DSTREAM-ST log
client:
• If CRC is enabled in the target device, ensure that CRC is enabled in the debug configuration
(
option).
HSSTP_CRC
• If CRC is not enabled in the target device, ensure that CRC is not enabled in the debug
configuration (
HSSTP_CRC
If this solution does not resolve the issue,
End of Frame (EOF) or First in First out (FIFO) overrun errors
EOF or FIFO overrun errors are indicated in the DSTREAM-ST log client.
Indicated by: A red General LED in the Errors LED section on the probe.
Solution
Contact Arm
support.
Bonding sequence transmission error
Bonding sequence transmission errors occur when the bonding sequence transmission length is
incorrectly set.
Indicated by: A green Lanes LEDs and a red Chan up LED on the probe.
Solution
In Arm Development Studio, check the bonding sequence transmission length that is set in the
python script for your target.
If the bonding sequence transmission length is set correctly,
Related information
Host Link issues
on page 35
Restore a DSTREAM-HT system
Copyright © 2019, 2022 Arm Limited (or its affiliates). All rights reserved.
contact Arm
option).
contact Arm
on page 37
Non-Confidential