Dstream-Ht Overheats; Arm Development Studio Invalid Trace - ARM DSTREAM-HT Getting Started Manual

Hide thumbs Also See for DSTREAM-HT:
Table of Contents

Advertisement

DSTREAM-HT Getting Started Guide

5.3 DSTREAM-HT overheats

The air intakes on the top of both the DSTREAM-ST unit and HSSTP probe, in a powered-up
DSTREAM-HT system, must remain clear.
Air intakes are blocked
If the air intake on the top of the DSTREAM-ST unit becomes blocked and the DSTREAM-ST unit
overheats, it shuts down, all the LEDs turn off, and it remains in a safe state.
If the air intake on the top of the HSSTP probe becomes blocked and the HSSTP probe overheats,
it enters a low-power mode and all of its LEDs flash red.
Solution
Check that the air intake is clear, and then press Reset on the rear of the DSTREAM-ST unit to
reinitialize the DSTREAM-HT system.

5.4 Arm Development Studio invalid trace

Invalid trace errors for Arm
probe.
Badly ordered data
If Arm Development Studio receives data in an incorrect order, it reports an
Indicated by: Arm Development Studio warning only.
Solution
Enable the HSSTP probe to reorder the data using the
Arm Development Studio.
If this does not resolve the issue,
Related information
HSSTP probe LED errors
Host Link issues
on page 35
Restore a DSTREAM-HT system
Copyright © 2019, 2022 Arm Limited (or its affiliates). All rights reserved.
Development Studio might not cause a red LED error on the HSSTP
®
contact Arm
support.
on page 34
on page 37
Non-Confidential
Document ID: 101760_1.0_02_en
Invalid trace
debug configuration setting in
HSSTP_NDALT
Version 1.0
Troubleshooting
error.
Page 37 of 39

Advertisement

Table of Contents
loading

Table of Contents