6 I/O Interface
6-4-1

FH-1000/2000/3000/5000 Series

Ethernet port differ depending on the Sensor Controller series. Refer to the followings, and confirm the
number of ports.
FH-1050/3050 (Camera 2ch type); Ethernet port is 1.
FH-2050/5050 (Camera 2ch type) and FH-1050-
type): Ethernet port is 2.
Ethernet port and Ether-
Net/IP port are sharing
use.
Cable
• Connect the LAN cable with a straight or cross cable.
• Use an STP (shielded twisted-pair) cable of category 5, 5e, or higher. Applicable EtherNet/IP com-
munications cables and connectors vary depending on the used baud rate.
• For 100Base-TX and 10Base-T, use an STP (shielded twisted-pair) cable of category 5 or higher. You
can use either a straight or cross cable.
• For 1000Base-T, use an STP (shielded twisted-pair) cable (double shielding with aluminium tape and
braiding) of category 5e or higher.
I/O Connector
• Electrical specifications: Conforming to IEEE 802.3 standards. Use RJ45 8-pin Modular Connector
(conforming to ISO 8877).
• When selecting a connector, confirm that it is applicable to the cable that will be used. Confirm the
following items: Conductor size, conductor type (solid wire or twisted wire), number of twisted pairs (2
or 4), outer diameter, etc.
6 - 50
FH-1050/FH-3050
0/2050-
0/3050-
0/5050-
FH-1050-10/-20, FH-3050-10/-20
FH-2000/5000 series
• Upper port:
Ethernet port
• Lower port:
Ethernet port and Ether-
Net/IP port are sharing use.