5 Setup and Wiring
Mounting of FH-1000/2000/3000/5000 Series
• Tighten the screws securely when installing the product.
• For good ventilation, provide a clearance of 50 mm or more above the sensor controller away from
other devices in the normal floor mounting. For the right and left sides, provide a clearance of 30 mm
or more, and for the back side, 15 mm or more. These clearances are also required when mounting
multiple sensor controllers side by side. For the side mounting, the side clearance of 30 mm is nor
required.
• Do not install the product immediately above significant heat sources, such as heaters, transformers,
or large-capacity resistors.
• Do not install the product in a cabinet containing high-voltage equipment.
• Do not install the Sensor Controller within 200 mm of power cables.
 Side Mounting
 Bottom Mounting
5 - 12
• Left side
4-M4 depth 4.5 (mounting screw hole)
143
* Recommended tightening torque: 1.2 N•m to 1.3 N•m
* The tolerance is ±0.2 mm.
• Bottom
4-M3 depth 4.5 (mounting screw hole)
* Do not remove the Insulating leg. Fix the Insulating leg to secure the ventilation path.
* Recommended tightening torque: 0.54 N•m to 0.6 N•m
* The tolerance is ±0.2 mm.
• Right side
4-M4 depth 4.5 (mounting screw hole)
19.2
19.5
182.5
20.1
(Unit: mm)
Insulating leg: 4
26.7
148.5
Vision System FZ5 series Hardware Setup Manual (Z423)