Fh-1000/2000/3000 Series - Omron FZ5 Series Hardware Setup Manual

Vision sensor
Hide thumbs Also See for FZ5 Series:
Table of Contents

Advertisement

5-8-2

FH-1000/2000/3000 Series

Precautions for Correct Use
Ambient Temperature
• Install and store the product in a location that meets the following conditions:
• Surrounding temperature of 0 to 50
• Relative humidity of between 35 to 85%RH
• Do not let the ambient temperature exceed 50
• Provide a forced-air fan cooling or air conditioning if the ambient temperature is near 50
(122°F) so that the ambient temperature never exceeds 50
Orientation of Product
• For good heat dissipation, install the product only in the position shown below so as not to
block the ventilation holes.
• Do not install the product in the following positions.
• For good ventilation, provide a clearance of 50 mm or more above the Sensor Controller
away from other devices in the normal floor mounting. For the right and left sides, provide a
clearance of 30 mm or more, and for the back side, 15 mm or more. These clearances are
also required when mounting multiple sensor controllers side by side. For the side mounting,
the side clearance of 30 mm is nor required.
Accessibility for Operation and Maintenance
When you connect the cable to the Sensor Controller, secure the minimum bending radius of the cable
or cable connector.
Connector length
Minimum bending radius
Vision System FZ5 series Hardware Setup Manual (Z423)
°C
°C
(-20 to +65
°C
(122°F).
Name
Camera Cable
Right-angle Camera Cable
Bend resistant Camera Cable
Bend resistant Right-angle
Camera Cable
Long-distance Camera Cable
Long-distance Right-angle
Camera Cable
5 Setup and Wiring
in storage)
°C
(122° F).
Minimum
Model
bending
radius
FZ-VS3
69 mm
FZ-VSL3
FZ-VSB3
FZ-VSLB3
FZ-VS4
78 mm
FZ-VSL4
°C
5
Connector
length
30 mm
42 mm
5 - 39

Advertisement

Table of Contents
loading

Table of Contents