Omron FZ5 Series Hardware Setup Manual page 83

Vision sensor
Hide thumbs Also See for FZ5 Series:
Table of Contents

Advertisement

Sensor Controller Series
Type
Sensor Controller Model
Ambient temperature range
Ambient humidity range
Ambient atmosphere
Vibration tolerance
Usage Envi-
ronment
Shock resistance
Noise
immunity
Grounding
Dimensions
External
Weight
Features
Degree of protection
Case material
*1. This can be increased up to 1024 using the Scene group conversion tool.
*2. Existing the third class grounding
Vision System FZ5 series Hardware Setup Manual (Z423)
Fast Transient Burst
FZ5-1200 series
High-speed Controller
FZ5-1200
FZ5-1205
Operating: 0°C to 45°C
(When the Built-in FAN is set to slow rotation.)
Operating: 0°C to 50°C
(When the Built-in FAN is set to fast rotation.)
Storage: -20 to +65°C
Operating and Storage: 35 to 85%RH (with no condensation)
No corrosive gases
Oscillation frequency: 10 to 150 Hz
Half amplitude: 0.1 mm
2
Acceleration:15 m/s
Sweep time: 8 minute/count
Sweep count: 10 times
Vibration direction: up and down/front and behind/left and right
2
Impact force: 150 m/s
Test direction: up and down/front and behind/left and right
• DC power
Direct infusion: 2 kV, Pulse rising: 5 ns, Pulse width: 50 ns,
Burst continuation time: 15 ms, Period: 300 ms, Application
time: 1 min.
• I/O line
Direct infusion: 1 kV, Pulse rising: 5 ns, Pulse width: 50 ns,
Burst continuation time: 15 ms/0.75 ms, Period: 300 ms,
Application time: 1 min
Class D grounding (100 Ω or less grounding resistance)
260 mm × 308 mm × 83 mm
Approx. 3.2 kg
IEC60529 IP20
ABS
3 Configuration
FZ5-1200-10
FZ5-1205-10
*2
260 mm × 308 mm × 104 mm
Approx. 3.4 kg
3 - 21