5 Setup and Wiring
Installation in a Control Panel
• Make sure to tighten all installation screws securely.
• To keep proper air flow, keep the top of the FH Sensor Controller 50 mm or more apart from other
devices. Install the FH Sensor Controller with a clearance of 30 mm on the right and left side, and 15
mm for rear planes. The clearance is required for installing multiple units side-by-side.
Side Mounting
Bottom Mounting
5 - 42
• Left side
4-M4 depth 4.5 (mounting screw hole)
143
* Recommended tightening torque: 1.2 N•m to 1.3 N•m
* The tolerance is ±0.2 mm.
• Bottom
4-M3 depth 4.5 (mounting screw hole)
* Do not remove the Insulating leg. Fix the Insulating leg to secure the
ventilation path.
* Recommended tightening torque: 0.54 N•m to 0.6 N•m
* The tolerance is ±0.2 mm.
• Right side
4-M4 depth 4.5 (mounting screw hole)
19.2
19.5
143
20.1
182.5
(Unit: mm)
Insulating leg: 4
26.7
148.5
Vision System FZ5 series Hardware Setup Manual (Z423)
(Unit: mm)