Couple Port - Agilent Technologies Agilent E5250A User Manual

Agilent technologies low leakage switch mainframe user's guide
Table of Contents

Advertisement

NOTE
Table 5-4

Couple Port

This function is available only for the E5252A.
Bias Port and Couple Port cannot be set to the same port number.
This function is used for making Kelvin connections. Couple port allows
synchronized connection of two adjacent input ports to two adjacent output ports.
You set up the Couple Port by using the [:ROUTe]:COUPle:PORT command
described in Chapter 7.
To turn Couple Port mode ON/OFF, refer to [:ROUTe]:COUPle[:STATe] command
in Chapter 7.
For a programming example, refer to Chapter 6.
The input ports 1 and 2, 3 and 4, 5 and 6, 7 and 8, or 9 and 10 can be coupled
together. See Table 5-4. For example, if you specify input port number 1 in the
[:ROUTe]:COUPle:PORT command, input ports 1 and 2 are coupled together.
Couple Port Number and Output Port Number
Couple
Input Ports
Port No.
01
SMU1, SMU2
03
SMU3, SMU4
05
SMU5, SMU6
07
09
Agilent E5250A User's Guide, Edition 11
Available Output Port No.
01 to 12 (for Normal Config.)
01 to 48 (for Auto Config.)
01 to 12 (for Normal Config.)
01 to 48 (for Auto Config.)
01 to 12 (for Normal Config.)
01 to 48 (for Auto Config.)
HF1, HF2
01 to 12 (for Normal Config.)
01 to 48 (for Auto Config.)
CV1, CV2
01 to 12 (for Normal Config.)
01 to 48 (for Auto Config.)
Controlling the E5250A
Switch Control Basics
5-13