Overview; Performance And Characteristics - Smartgen HGM400N Series User Manual

Genset controller
Hide thumbs Also See for HGM400N Series:
Table of Contents

Advertisement

1

OVERVIEW

HGM400N series genset controller integrates digitization, intelligence and network technology together,
which is used for single unit automation and monitoring control system, to achieve functions of
automatic start/stop, data measurement, alarm protection, etc. It fits with LCD display, optional
language interface (Chinese, English, Spanish, Turkish, Russian and French). It is reliable and easy to
operate.
HGM400N series genset controller adopts micro-processor technology, realizing precise parameter
measuring, fixed value adjustment, time setting and set value adjusting etc. All parameters can be
configured from front panel, or they can be modified and monitored through USB interface by using PC.
It can be widely used in all types of automatic genset control system with compact structure, simple
wirings and high reliability.
2

PERFORMANCE AND CHARACTERISTICS

HGM400N series controller has two types:
HGM410N: used for automation of single unit, which controls generator to start/stop by remote start
signal.
HGM420N: based on HGM410N, AMF (Auto Mains Failure) and Mains/Gens automatic transfer control
functions are added, which is especially suitable for single unit automation system composed by one
mains and one gens.
Main characteristics are as below:
 132x64 LCD with backlight, selectable language interface (Chinese, English, Spanish, Turkish,
Russian and French), push-button operation;
 Improved LCD wear-resistance and scratch resistance due to hard screen acrylic;
 Silicon panel and pushbuttons for better operation in high/low temperature environment;
 Suitable for 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with
voltage 120/240V and frequency 50/60Hz;
 Collects and shows 3-phase voltage, 3-phase current, power parameter and frequency of generator
or mains;
Mains
Line Voltage (Uab, Ubc, Uca)
Phase Voltage (Ua, Ub, Uc)
Frequency (Hz)
Phase Sequence
Load
Current (IA, IB, IC)
Split-phase and Total Active Power (kW)
Reactive Power (kvar)
Apparent Power (kVA)
Power Factor (PF)
Accumulated Gen Energy (kWh)
Output Percentage with Load (%)
 For Mains, controller has over voltage, under voltage and loss of phase detection functions; For
HGM400N Series Genset Controller User Manual
Generator
Line Voltage (Uab, Ubc, Uca)
Phase Voltage (Ua, Ub, Uc)
Frequency (Hz)
Phase Sequence
Page 4 of 38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hgm410nHgm420n