Remote Sensor Pairing Instructions – Multiple Sensors (Wireless)
Fig. 1
Fig. 2
47
If using multiple remote temperature/humidity sensors in your
application, refer to the figures and the procedure below to change
each remote sensor's device number (Three Remote Sensors
maximum). Each Remote Sensor must have its own device number
and must also be on the same RF channel (Setting 31) as the
system they are being paired with.
1. To change the remote sensor's device number, see the
following instructions:
a. Use a pin to press the button for about half a second and
release (Fig. 1).
b. Observe the LED on the side of the remote sensor (Fig. 2).
The LED will flash once for a Device #1, twice for a #2,
three times for a #3. At any time, while in this mode press
the button once to change the device number. Once each
remote sensor has its own unique device number simply
wait for the LED to stop flashing and the setting will be
saved.
2. To change the remote sensor's RF channel, see the
following instructions:
NOTE: Check what RF Channel the System is set to
using Setting 31 to more easily connect your Remote
Sensors.
a. Use a pin to press the red button at the back of the Remote
Sensor for 5 seconds until the LED blinks rapidly then
release the button.
b. The LED will flash a number of times to portray which RF
channel it is set to and repeat a total of 3 times.
c. To change the RF channel, press the button once to
increment the RF channel. There are 12 possible RF
channels. All Remote Sensors will need to be on the same
channel for the system to detect them. To save the RF
channel setting simply wait for the mode to time out by not
pressing the button.