Fan AUTO or
ON
Compressor
anti-short
cycling
Defrost sensor
enable/disable
Defrost cut-in
temperature
33
Setting 7
Press "Settings" button to advance to
Setting 7.
Press the "Up" or "Down" arrow buttons
to adjust number to the desired set point.
Factory default is zero (0).
Zero (0) = Auto–fan only turns on when
there is a call for cooling or heating
One (1) = Fan On–fan remains on
continuously
Setting 8
Press "Settings" button to advance to
Setting 8.
Press the "Up" or "Down" arrow buttons
to adjust to the desired time in one-minute
increments. Maximum is 10 minutes,
minimum is 3 minutes. Factory default is 5
minutes.
Compressor anti-short cycling time is the
amount of allowable time between
compressor stop and restart. Rapid
start/stop of compressors can cause
premature failure.
WINE GUARDIAN DOES NOT
RECOMMEND SETTINGS LOWER
THAN FACTORY DEFAULT.
Setting 9
Press "Settings" button to advance to
Setting 9.
Press the "Up" or "Down" arrow buttons
to adjust to the desired setpoint.
1 will equal enabled and a 0 (zero) will
equal disabled.
Setting 10
Press "Settings" button to advance to
Setting 10.
Press the "Up" or "Down" arrow buttons
to adjust to the desired setpoint. This
setting is adjustable from 25°F to 40°F.
Factory default is 39°F.
There must be at least a 1°F difference
between defrost cut-in and cut-out set
points.