Problems Controlling Cellar Humidity; Other Miscellaneous Problems - Wine Guardian TTW018 Installation, Operation And Maintenance Manual

Through-the-wall wine cellar cooling systems
Table of Contents

Advertisement

Problems Controlling Cellar Humidity

Humidity too high when unit is not
running
Possible Cause
System needs to run to dehumidify
Humidity too high when unit is running
and cooling
Possible Cause
Too much moisture in cellar

Other Miscellaneous Problems

System is leaking water
Possible Cause
Condensate pan plugged
Unit not level
System is running properly, but the sounds
of unit is objectionable
Possible Cause
Noise is from airflow
54
Solution
Lower room temperature setpoint. Seal
openings around doors (gasket and sweep)
Solution
Poor vapor barrier installation
Humidifier malfunction refer to the humidifier
instructions
Add dehumidifier to surrounding space
Solution
Remove blockage and clean
Level with shims
Solution
Duct airflow from condenser to outdoors