Settings – Press and hold the "Settings" button for five (5) seconds to access the
following settings.
Degrees F or
Degrees C
Low
temperature
alarm setpoint
High
temperature
alarm setpoint
Low humidity
alarm set point
High humidity
alarm setpoint
Add or remove
humidifier
32
Setting 1
Press the "Up" arrow to change
temperature from °F to °C.
Press the "Down" arrow to change
temperature from °C to °F.
Setting 2
Press "Settings" button to advance to
Setting 2.
Press the "Up" or "Down" arrow buttons
to adjust to the desired setpoint. Factory
default is 50°F (10°C).
Setting 3
Press "Settings" button to advance to
Setting 3.
Press the "Up" or "Down" arrow buttons
to adjust to the desired setpoint. Factory
default is 65°F (18°C).
Setting 4
Press "Settings" button to advance to
Setting 4.
Press the "Up" or "Down" arrow buttons
to adjust to the desired setpoint. Factory
default is 5%.
Setting 5
Press "Settings" button to advance to
Setting 5.
Press the up or down arrow buttons to
adjust to the desired setpoint. Factory
default is 95%.
Setting 6
Press "Settings" button to advance to
Setting 6.
Press the "Up" or "Down" arrow buttons
to adjust to the desired setpoint. Factory
default is zero (0).
Zero (0) = No humidifier
One (1) = Integral Wine Guardian
mounted humidifier
Two (2) = Stand-alone remote mounted
humidifier